NEC
Inductors
Capacitors
Elect. Safety
C,S and P
100

The minimum cover requirement for underground feeder and branch circuit Type UF cable used as a 30 amp feeder under a driveway for a 2 family dwelling

18 in.  Art. 300.5 (A)

          Table 300.5

100

EMF and CEMF are _____ degrees out of phase with each other

A. 90 degrees

B. 180 degrees

C. 270 degrees

D. 360 degrees

B. 180 degrees

100

Capacitance is measured in _______.

Farads

100

A major short circuit or ground fault at the main service panel or meter socket panel is called ___.

Arc Flash

100

Equipment that is constructed so that moisture will not enter the enclosure under specified test conditions would be classified as ______.

Watertight

200

Type NM cable with a 1/2 in. diameter shall be installed so that the inner edge of any bend is not less than:

2 1/2 inches.   334.24

200

Inductors are measured in _______.

Henries

200

Capacitors ______ electrical charge

Store

200

NFPA 70 E considers conductors not electrically safe until:

A. All sources of energy are removed

B. LOTO at disconnecting means

C. Absence of voltage is verified by an approved meter

D. All the above

D. All the above

200

Conductors and equipment required or permitted by this code shall be acceptable only if_____.

A. Listed

B. Certified

C. Approved

D. Documented

C. Approved

300

Insulated conductors for non-metallic sheathed (Type NM) cable shall be rated at:

A. 140 degrees F

B. 167 degrees F

C. 194 degrees F

D. 120 degrees F

C. 194 degrees F   

Art. 334.112

300

Current _______ voltage in an inductive circuit.

A. Lags

B. Leads

A. Lags

300

The insulating material in a capacitor is called____.

The dielectric

300

OSHA recognizes these as the 4 main types of electrical injuries

Electrical Shock

Electrocution

Burns

Falls

300

NEC Table 8 of Chapter 9 may be used to find the ___ of a conductor.

Resistance

400

A small appliance branch circuit in a dwelling shall comply with which of the following?

A. Have no lighting outlets supplied to it

B. limited to 4 outlets and 4 lights

C. Have 15A OCPD

D. Be permitted in the living room

A.  Have no lighting outlets supplied by it.

Art. 210 (C)(1) and 210.52 (B)(1)

400

Total opposition to the AC circuit is called_____.

Impedance

400

In a purely capacitive circuit, current can only flow during the time the capacitor is___.

Charging or discharging

400

Who is mainly responsible for Safety 

YOU

400

Heat generated internally in a conductor is the direct result of load____.

A.  Current

B.  Resistance

C.  Voltage

D.  Wattage

A.  Current

500

Equipment grounding conductors are permitted to be any of the following EXCEPT:

A. Stranded bare wire

B. Bare circular busbar

C. A surface metal raceway listed for grounding

D. 6 1/2' of listed flexible metal conduit

D. 6 1/2' of listed flexible metal conduit.

Art. 250.118 (5)(d)

500

The formula to find Inductive Reactance is_____

X(L)= 2(3.14)FL

500

One time constant is the amount of time it takes for a capacitor to_____% of the time left to reach its full charge.

63.2%

500

What does the letters NFPA stand for?

National Fire Protection Agency

500

Non-metallic sheathed cable wiring is generally used in a _____ location.

Dry

M