Service Entrance and Feeders
Overhead and Underground Services
Underground Services and Protection
Emergency Disconnects, Service Equipment and SPDs
Chicken Jockey
100

This term refers to all circuit conductors between service equipment and the final branch circuit overcurrent device.

What is a Feeder

100

These overhead conductors are installed, owned, and maintained by the utility, not the electrician .

What is the service drop

100

This NEC section requires protection of underground service entrance conductors against physical damage.

What is NEC 230.50

100

This NEC section requires an emergency disconnect in a readily accessible outdoor location for one and two family dwellings 

What is NEC 230.85

100

what is 77+33

110

200

This NEC article contains the definition of "service" and "service point".

What is NEC Article 100

200

This minimum clearance is required above a residential driveway for service conductors under 300 volts to the ground.

What is 12 Feet
200

This minimum burial depth is required for most residential underground service laterals

What is 24 Inches

200

This marking must appear on a service disconnect used as the emergency disconnect.

What is Emergency Disconnect/Service Disconnect.

200
How many planets are there in our solar system 
300

This is the point where the utility's wiring ends and the customers wiring begins.

What is the Service Point

300

This type of service uses conductors or cable installed underground from the utility system to the service equipment.

What is an Underground Service 

300

This Warning material must be installed above underground wiring per NEC 300.5 (D) (3).

What is Buried electric warning ribbon 

300

This is the type of surge protective device is installed on the line side of the service disconnect

What is a Type 1 SPD

300

Name All 7 Continents 

North America, South America, Africa, Europe, Australia, Antarctica, Asia. 
400

This minimum ampacity is required for a one family dwelling service disconnect according to NEC 230.79 (C).

What is 100 amperes

400

Only these types of conductors are allowed to be attached to a service mast according to NEC 230.28.

What are Power service drop or overhead service conductors.

400

These conductors typically run from a pad mounted transformer to the meter location in an underground service.

What are service lateral conductors.

400

This NEC section requires every circuit and circuit modification to have a clear, permanent description 

what is NEC 408.4

400

who won in Shawn v Lekki

Shawn

500

These conductors run from the service equipment to the first overcurrent device of a branch circuit.

What are Feeder Conductors 
500

This fitting is used where a service raceway passes through a roof to prevent water intrusion.

What is a Neoprene seal with metal flashing 

500

This NEC table is used to determine burial depth for underground wiring

What is NEC Table 300.5

500

This minimum nominal discharge current rating is required for SPDs installed at services 

What is 10 kA

500
Do 15 Push ups each or your team loses 500 points 