Compliance or Die
Tons of Fun
Under Pressure
Subcooled & Confused
Frosty the Heat Pump
100

Effective January 1, 2026, under the 2025 California Energy Code, the HERS compliance program was officially renamed to ECC, which stands for these three words.

What is Energy Code Compliance?

100

Equal to 12,000 BTUs per hour, this standard unit measures residential air conditioning cooling capacity.

What is one ton?

100

This three-letter acronym measures the volume of air moving through a duct system in Cubic Feet per Minute.

What is CFM?

100

Often called the "heart" of the air conditioner, this outdoor component pumps refrigerant through the system and raises its pressure and temperature.

What is the compressor?

100

Unlike a gas furnace, an all-electric heat pump does not burn fuel to create heat—instead, it does this with existing heat energy.

What is moves (or transfers) heat?

200

Mounted in an exterior doorway, this diagnostic fan depressurizes a house to measure air leakage in CFM50.

What is a blower door?

200

This component on a heat pump switches the direction of refrigerant flow so the system can either heat or cool a home.

What is a reversing valve?

200

Used by HERS raters during duct leakage testing, this device pressurizes the duct system to 25 Pascals to measure air loss.

What is a Duct Blaster?

200

On a standard 24-volt thermostat wire bundle, this colored wire traditionally powers the cooling contactor (Y) while this other color is used for the common wire.

What are yellow and blue (or black/brown for C)?

200

During freezing winter weather, a heat pump temporarily switches into cooling mode with the outdoor fan off to melt ice off the outdoor coil during this cycle.

What is the defrost cycle?

300

Under the 2025 Energy Code transition, California moved ECC field verification and diagnostic testing regulations out of Title 20 and directly into this specific title of the California Code of Regulations.

What is Title 24 (specifically Part 1, Section 10-103.3 and Part 6)?

300

This modern cooling efficiency rating replaced SEER in 2023 to better account for real-world duct static pressure.

What is SEER2?

300

For a standard residential air handler, technicians generally aim for this target airflow rate per ton of cooling capacity.

What is 400 CFM per ton (or 350 to 450 CFM per ton)?

300

Measured on the suction line entering the compressor, this reading ensures no damaging liquid refrigerant reaches the compressor.

What is superheat?

300

Unlike an HRV, this balanced ventilation unit transfers both heat and moisture (humidity) between incoming and outgoing air streams

What is an Energy Recovery Ventilator (ERV)?

400

In California Title 24 compliance documentation, this specific "CF" certificate is completed and registered by the independent ECC-Rater after passing field verification and diagnostic testing.

What is a CF3R (Certificate of Verification)?

400

Under the EPA AIM Act transition, traditional R-410A is being replaced by mildly flammable refrigerants classified under this ASHRAE safety group.

What is A2L (such as R-454B or R-32)?

400

Measured in Inches of Water Column, this total resistance figure is found by adding external supply static pressure and return static pressure together.

What is Total External Static Pressure (TESP)?

400

Under the 2025 Energy Code ECC rules for refrigerant charge verification, a Fault Indicator Display (FID) alone can no longer be used to show compliance—raters must verify charge using subcooling/superheat or this alternative method.

What is the weigh-in method (verified by the ECC-Rater)?

400

Unlike single-stage compressors that run only at 100% capacity, this technology uses variable-frequency drives to modulate compressor speed smoothly, boosting part-load efficiency and dehumidification.

What is an inverter-driven (or variable-speed) compressor?

500

During combustion safety testing, raters depressurize the Combustion Appliance Zone (CAZ) to its worst-case scenario to verify that natural-draft appliances do not experience this hazardous failure mode

What is backdrafting (or spillage)?

500

In the ACCA residential design suite, Manual J calculates heating and cooling loads and Manual S selects equipment, while this specific manual governs duct sizing and friction rates.

What is Manual D?

500

When performing a duct leakage to the outside test, raters run a blower door and a Duct Blaster simultaneously to neutralize pressure across the building envelope—a technique known by this term.

What is guarded duct leakage testing (or the subtraction method)?

500

Unlike a fixed-orifice piston, this metering device uses a sensing bulb strapped to the suction line to actively modulate refrigerant flow and maintain constant superheat.

What is a Thermostatic Expansion Valve (TXV)?

500

Installed inside the indoor air handler, these high-wattage resistance coils kick on to supplement heat pump capacity during extreme cold snaps or defrost cycles.

What are auxiliary heat strips (or electric resistance backup heat)?