THE 2 DIRECTIONS IN WHICH VENTILATION CAN BE ACHEIVED
HORIZONTAL AND VERTICAL
A SOLID BORE NOZZEL PROVIDES A _____ STREAM OF WATER.
SOLID
THE 5 TYPES OF BUILDING CONSTRUCTION
TYPE 1 - FIRE RESISTIVE
TYPE 2 - NON COMBUSTIBLE
TYPE 3 - ORDINARY
TYPE 4 - HEAVY TIMBER
TYPE 5 - WOOD FRAME
_______ ____ IS THE TEMPERATURE IN WHICH A LIQUID WILL CONTINUOUSLY GIVE OFF VAPORS IN SUSTAINED AMOUNTS, AND IF HELD AT THIS TEMPERTURE FOR LONG ENOUGH, WILL TURN COMPLETELY INTO GAS.
BOILING POINT
STRUCTURE FIRE RESPONSE
4 ENGINES
2 LADDERS
RESCUE OR SQUAD
2 BATT CHIEFS
ISO14
THE 3 METHODS OF VENTILATION
NATURAL (HOLES AND WINDOWS)
MECHANICAL (PPF AND SMOKE EJECTOR)
HYDRAULIC (FOG STREAMS)
A FOG NOZZLE PROVIDES A ______ STREAM
BROKEN
A ___ _______WALL SUPPORTS OR PARTIALLY SUPPORTS THE WEIGHT OF A BUILDING.
LOAD BEARING
________ _____ IS AN EXPRESSION OF FUEL/AIR MIXTURE DEFINED BY UPPER AND LOWER LIMITS.
FLAMMABLE RANGE
WATCH HOURS
0800-2100
F
T
B
C
FAR
TOP
BOTTOM
CLOSE
A ____ IS USED TO JOIN TWO FEMALE HOSE COUPLINGS
DOUBLE MALE
1. A ROOF THAT FEATURES SLOPING OR INCLINED SURFACES
2. A ROOF THAT DOES NOT FEATURE SLOPING OR INCLINED SURFACES
1. PITCHED ROOF
2. FLAT ROOF
_____ ___ IS THE MINUMUM TEMPERATURE A SUBSTANCE EMITS ENOUGH VAPOR TO FORM AN IGNITABLE MIXTURE BUT NOT SUSTAIN CUMBUSTION.
TRUE OR FALSE
AN AERIAL APPARATUS CAN BE USED TO STANDBY AT A HYDRANT OF ESTABLISH A WATER SUPPLY
FALSE
THIS CUT METHOD IS PRIMARILY USED TO STOP OR SLOW FIRE PROGRESSION IN LONG, NARROW BUILDINGS SUCH AS STRIP MALLS AND STORAGE UNITS
TRENCH CUT
WHICH OF THE FOLLOWING HOSE SIZES CANNOT BE USED AS SUPPLY HOSE?
A. 3"
B. 2 1/2"
C. 1 3/4"
D. 4"
C. 1 3/4'
A CONSTRUCTION METHOD TO SUPPORT FLOORS AND ROOFS. IT CONSISTS OF SMALLER DIAMETER LUMBER JOINED TOGETHER TO FORM A STRONG, SINGLE SUPPORT MEMBER. IT IS COST EFFECTIVE COMPARED TO SOLID, HEAVY TIMBER CONSTRUCTION.
TRUSS CONSTRUCTION
A MATERIAL WITH A PH VALUE GREATER THAN 7
BASE
PERSONAL FLOATATION DEVICE SHALL BE WORN WITHIN __ ___ OF THE WATER EDGE
10 FEET
THIS CONDITION OCCURS WHEN THERE IS A SIGNIFICANT TEMPERATURE DIFFERENCE BETWEEN OUTSIDE AIR AND THE AIR INSIDE A BUILDING (TYPICALLY HIGH RISE BUILDINGS) DURING AN ACTIVE FIRE.
EXAMPLE - THE FIRE IS ON THE TOP FLOOR BUT SMOKE CONDITIONS ARE WORSE ON THE GROUND FLOOR.
STACK EFFECT
WINTER AND SUMMER
NOZZLE OPERATING PRESSURES (IN PSI)
1. SMOOTH BORE HANDLINE ____
2. LOW PRESSURE FOG ____
3. SMOOTH BORE MASTER STREAM _____
4. STANDARD FOG _____
1. 50 PSI
2. 50 PSI
3. 80 PSI
4. 100 PSI
A _______ ___ IS BEST DESCRIBED AS A SECTION OF WALL THAT APPEARES TO BE LOAD BEARING BUT IS ACTUALLY NOT AND IS STRICTLY FOR ASTHETICS ONLY. THESE WALLS ARE TYPICALLY BRICK AND/OR LAYERD STONE.
VENEER WALL
THE WEIGHT OF AN AIRBORN CONCENTRATION (VAPOR OR GAS) COMPARED TO WEIGHT OF AIR.
VAPOR DENSITY
IF OXYGEN CONCENTRATIONS IN A SPACE DROP BELOW ____ MEMBERS SHALL WEAR SCBA
19.5%