Photovoltaic Integration
NEBF
Photovoltaic Interconnection
Installing Trays and Raceways
NEC for Solar Photovoltaics
100

The maximum voltage drop recommended for PV systems.

What is 2-3%?

100

The year the NEBF was created.

When was 1927?

100

With this type of system, utility customers are served by both the centralized power plant and the power exported from interconnected, smaller power generating systems.

What is interactive?

100

The percentage the installation of circuits in wire mesh cables trays is faster than traditional methods.

What is 20-30%?

100

What, in addition to being polarized, the connectors in a PV system must be with receptacles of other systems on the premises.

What is Noninterchangeable? 

200

Must be present on the AC side of the PV system to isolate the system from the rest of the buildings electrical system.

What is a Disconnect?

200

You are vested after this many years.

What is 5?

200

In Bimodal systems this can continue to supply power to certain loads in the event of a utility outage.

What is an Inverter?

200

States the uses not permitted for surface non metallic raceways.

What is NEC Art. 388.12?

200

This is required between a PV array and other equipment in accordance with Section 250.110.

What is an Equipment Grounding Conductor?

300

A mechanically integrated assembly of modules and panels with a support structure and foundation, tracker and other components as required to form a DC or AC power producing unit.

What is an Array?

300

The percentage of their covered employees gross labor payroll employers contribute to the NEBF each month.

What is 3%?

300

What most power generated by rotating generators require to avoid damage to the equipment and the utility.

What is Precise Interconnection?

300

Where it states that for power circuits, an equipment grounding conductor must be provided.

What is NEC Art. 388.60?

300

What live parts of battery systems for dwellings shall be to prevent accidental contact by persons or objects, regardless of voltage or battery type.

What is Guarded?

400

Photovoltaic equipment and systems along with all of their associated wiring and interconnections shall only be installed by.

Who are qualified persons?

400

The amount an electrician with 35 year of service would receive from the NEBF if they retire at age 65.

What is $1120 per month?

400

A system in which many smaller power generating systems create electrical power near the point of consumption.

What is Distributed Generation?

400

The way cable tray systems shall be installed.

What is as a complete system?

400

What Photovoltaic systems used directly to charge electric vehicles shall comply with in addition to Art. 690.

What is Article 625?

500

Multiple PV source circuits are joined into the PV output circuit here.

What is a Combiner Box?

500

When the NLRB ruled that the member must have worked for a "covered" employer to be eligible.

When was 1957?

500

The undesirable condition where a distributed generation power source continues to supply power to the utility grid during a power outage.

What is Islanding.

500

Shall be provided to prevent stress on cables where they enter raceways from cable trays.

What are supports?

500

Must be provided when a building has both a utility service and a PV system to show the locations of their disconnecting means.

What is a Permanent Plaque or Directory?