This protection plan level is specifically recommended as the best fit for newer HVAC systems under 5 years old.

What is Cardinal Comfort Care?  

100

A DIRTY ONE OF THESE CAN CAUSE BURNERS TO SHUT DOWNAFTER A FEW SECONDS

WHAT IS THE FLAME SENSOR?

100

These are the photos you are required to take on service jobs

Must get 3 of the 4


• Equipment data plates 

• Before and after photos of any work performed

• Photos with Cardinal stickers

• Yard signs

100

TWO TYPE OF CAPACITORS ARE THERE IN AN HVAC SYSTEM

WHAT IS?

RUN CAPACITORS AND START CAPACITORS

100

A MOTORIZED OR MANUEL FLAP INSIDE THE DUCTWORK THAT OPENS AND CLOSES TO CONTROL AIRFLOW TO A ZONE

WHAT IS? 

ZONE DAMPER 

200

What does Airflow / Filter Sensor measure to alert the customer to change the filter.

What is: exact pressure changes to determine when a filter is actually 90% clogged 

200


At what temp does a heatpump no longer produce heat?

35

200

How many microns are you required to pull a vacuum down to?

500 microns or lower

200

What does HVAC stand for

Heating, Ventilation, and Air Conditioning

200

RECEIVES THERMOSTAT INPUTS FROM MULTIPLE ZONES AND TELLS DAMPERS WHEN TO OPEN AND CLOSE AND THE HVAC EQUIPMENT WHEN TO RUN

What is a Zone Board

300

 To avoid false positives created by condensation, a technician must attach this magnetic accessory to the water sensor before placing it pins-down in the drain pan.  

What is a Water Riser?

300

 TXV is often incorrectly blamed as the culprit for a faulty HVAC system instead of _______. 

What is: Improper system sizing. 

300

This is the number of solutions we should be building for a system 5-9 years old, and how to be presented? 

3 solutions

A  (Repair)

B (Restoration)

C (Replacement)

300

Roleplay the proper greet 

Van Check

Verify the reason you are out

Time commitment 

Permission Statement 

Booties

300

What is the device that pulls heat from the condensor

What is Condensor fans?

400

To guarantee member priority, Cardinal promises VIP same-day scheduling for no heat, no cool, or no water emergencies, provided the call is booked before this specific time.

What is 10:00 a.m.?

400

The correct sequence of operations for a cooling demand job

  • Verify thermostat call: Ensure the thermostat is set to cool and actively calling for cooling ($Y$ terminal energized).

  • Check indoor blower: Confirm the indoor fan is running and moving air across the evaporator coil.

  • Inspect outdoor unit: Check if both the condenser fan motor and the compressor are running.

  • Test electrical controls: Measure voltage at the contactor, check dual capacitors, and inspect safety switches (like condensate overflow or high/low pressure switches).

  • Check refrigerant pressures: Hook up gauges to measure subcooling and superheat to diagnose a charge or metering device issue.

400

When setting a lead to a project manager these items must be confirmed first

Must have 3 of the 4 options


The customer has been presented with repair options

• The customer has confirmed that they want to speak with a PM about replacement options

• A thorough summary of findings has been prepared for both the customer and for the PM

• Photos have been taken of the area of concern

400

This is our mission statement 

To genuinely serve and improve lives with honesty and integrity.

400

RECEIVES THERMOSTAT INPUTS FROM MULTIPLE ZONES AND TELLS DAMPERS WHEN TO OPEN AND CLOSE AND THE HVAC EQUIPMENT WHEN TO RUN

WHAT IS? 

ZONE BOARD 

500

The cost of of adding an additional zone to the plan

What is $9.99

500

A DIRTY ONE OF THESE CAN CAUSE LOW AIRFLOW, HIGH HEAD PRESURE, OR A FROZEN COIL.

What is an Air Filter
500

Explain the call out procedure

Call your direct super supervisor (Patrick for Sales, Amanda for Service, Champ for Install)


Provide DR note or work the weekend

500


• Ask if spouse is available to speak with

• What would spouse say if they were here?

• What questions do you think your spouse may have?

• Set up a time to follow up (specific date / time)

500

How much gas pressure are you suppose to get going thru the Gas Regulator ?

Natural GAS

  • Standard Appliance Inlet Pressure: 5" to 7" WC
  • Manifold (Burner) Pressure: 3.5" WC
M