What does the "Live-Dead-Live" test verify?
That voltage tester is working before and after verifying the absence of voltage.
What is one possible consequence of an Arc Flash explosion?
A) Minor skin irritation only
B) Severe burns, eye injuries, and hearing loss
C)Muscle fatigue
B) Severe burns, eye injuries, and hearing loss
Check that digital multi-meter is rated CAT ____ , 600 Volts or higher.
CAT III
With insulated leads with finger guards to keep hands / fingers clear of energized parts.
What does GFCI stand for?
Ground Fault Circuit Interrupter
Which country has the most elevators per capita in the world?
A) Spain
B) Japan
C) China
Spain!
20 elevators for every 1,000 people.
Canada: 4 elevators for every 4 people.
Which are the 3 elevator components more involved in user fatalities?
-Brake
-Landing Door
-Safety circuit
When should insulating barriers or guards be used?
A) During every electrical inspection
B)When an electrically safe working condition cannot be achieved through de-energization and Lockout/Tagout
C)Only when working above 600 volts.
B)When an electrically safe working condition cannot be achieved through de-energization and Lockout/Tagout
Energized parts that operate at less than 50 volts to ground potential are not required to be de-energized if there will be no increased exposure to electrical burns or explosion due to electric arcs.
A) False
B) True
B) True
What is the minimum number of personal locks each employee must have?
Three red locks and one yellow lock
Approximately how many elevators are in operation worldwide?
A) About 5 million
B) About 20 million
C) About 100 million
B) About 20 million
Golden Rules
I respect safety instructions and training and STOP work if I have any doubt
• I use Personal Protective Equipment, the right tools and methods
• I behave as a Safety role model
• I report Unsafe Events and prevent recurrences
• I identify hazards, keeping workplaces safe and tidy
What does "Working On" electrical circuits mean?
A) Working near electrical equipment)
B) Intentionally contacting energized conductors or circuits with hands, body parts, tools, probes, or test equipment.
C)Performing inspections after Lock Out Tag Out
B) Intentionally contacting energized conductors or circuits with hands, body parts, tools, probes, or test equipment.
Describe the rule: 18, 50.
Arc-flash rated gloves and sleeves must be worn when working within 18” (45cm) of exposed energized circuits operating at 50 Volts and higher.
When installing physical or mechanical barriers how close can they be placed to energized parts?
A) No closer than 24 inches
B) No closer than 5 feet (1.5 m)
C) No closer than the restricted approach distance of 18" (45.7 cm).
C) No closer than the restricted approach distance of 18" (45.7 cm).
What is the longest escalator in the world?
A) About 80 m
B) About 120 m
C) About 138 m
C) About 138 m
Central - Mid- Levels Escalator system in Hong Kong
What is the am I ready check list?
Am I present (all distractions are eliminated, my head is clear, I can focus on the task)?
• Do I understand the task?
• What hazards are present that pose a risk and are any LIFESaving related (fall, electrical, caught in or struck by)?
• What hazard reduction tools will I use?
• What can go wrong (consider worst case)?
• What hazards would stop this task?
• How do I communicate the hazards and risks I’ve identified to those I am working with or around?
What is the difference between an Arc Flas and an Electrical Shock?
An Arc flash is exposure to thermal energy from an electrical arc.
While an Electrical Shock occurs when electrical current passes through the body.
Which are the two categories of "Working On" electrical circuits?
A) Maintenance and Installation
B Inspection and Commissiong
D) Diagnostic Testing and Repairs
D) Diagnostic Testing and Repairs
Escalators
Strap Requirement for Blocking Steps: Ratchet straps or synthetic slings must be padded and rated at minimum __________ capacity each when used for securing drive chain and steps from movement or slippage in both directions.
minimum 1,134kg (2500 lb.)
Where was the world's first working escalator installed?
A) London, England
B) Coney Island, NY, USA
C) Paris, France
B) Coney Island, NY, USA

Hazard controls must be addressed in which order of priority? (HIERARCHY OF CONTROLS)
Elimination, Substitution, Engineering, Administrative, and PPE.
What does the "11 cal/cm2 marking on these gloves represent?
A) The maximum voltage the gloves can withstand.
B) The number of incidents thermal energy the gloves are rated to protect against during Arc Flash.
C. The maximum temperature the glove can reach.
B) The number of incidents thermal energy the gloves are rated to protect against during Arc Flash.
When work is being performed inside the truss of an escalator, electrical and mechanical energy must be controlled at all times by 2 independent means as follows:
1. Lock Out Tag Out the mainline disconnect. This serves as the electrical isolation.
2. Mechanically block the steps in both directions using redundant means. This can be accomplished by any 2 of 3 means.
Mechanically block the steps in both directions using redundant means. This can be accomplished by any 2 of 3 means:
_________
_________
_________
• Place a lock bar or locking pin at the machine drive;
• Setting the machine brake;
• Use of straps in both directions. If not able to block the machine drive, then place two straps in each direction between step band and truss preventing movement in each direction (total of 4 straps).
Approximately how many employees does Schindler have worldwide?
A) 66,000
B) 90,000
C) 70,000
C) 70,000