Tactical Ventilation Basics
Ventilation Methods & Equipment
Fire Hose Basics
Hose Couplings & Maintenance
Hose Rolls & Loads
100

Tactical ventilation is performed during fire attack for this primary purpose.

Help control the fire

100

This type of mechanical ventilation involves artificially lowering the pressure inside the structure.

Negative pressure ventilation

100

This type of hose transports water from the pumping apparatus to the nozzle.

Attack

100

This specific type of hose coupling features the thread on the exterior.

Male

100

This type of hose roll is commonly used when storing hose in a storage rack.

Straight roll

200

Thi is the primary mode of heat transfer from one compartment to another in a structure fire.

Convection

200

This type of ventilation requires no additional personnel or equipment to set up and maintain.

Natrural horizontal ventilation

200

Fire hose is labeled and identified according to this specific measurement.

Inside diameter

200

This is the primary purpose of lugs found on a fire hose coupling.

Tightening and Lossening

200
In this hose load, the hose lays on its edge in folds that lay next to eachother.

Accordion

300

This rapid transition occurs when fresh air from ventilation is introduced into a room, causing gases to ignite.

Flashover

300

This air movement equipment is used specifically to perform hydraulic ventilation.

Hoselines and fog nozzles

300

This type of hose is designe to connect the pumping apparatus to a pressurized water source.

Large diameter hose (LDH)/Supply
300

This feature on a coupling is a flattened angle at the end of the threads that helps prevent cross-threading.

Higbee Cut

300

To make loading LDH more efficient, many apparatus are equiped with this piece of hardware.

Hose roller

400

Maintaining control over this may improve visiblity inside structures so that interior crews can work more effectively.

Exhaust openings

400

To be effective, vertical ventilation requires a horizontal inlet opening at this location.

At or below fire level
400

Booster hose is designed to be carries in this manner on the fire apparatus.

On reels mounted on the apparatus

400
In order to prevent mildew, this specific type of hose must be dried before being stored.

Woven-jacket natural fiber

400

This preconnected hose load consists of folds laid into the hose bed in an S-shape.

Triple layer

500

When wind speeds are 10mph or faster, firefighters are safest working in this postion.

Wind at their backs (upwind)

500

This type of cut is performed to create a defensivle line ahead of a fire's spread.

Trench cut

500

Fire hose should be service tested at least this often after its initial placement in service.

Once a year

500

Exposure to this substance will react to rapidly separate the inner lining of the fire hose.

Gasoline
500

This hose load can be carried completely on the shoulder and clear of the ground, reducing the chance of catching on obstacles.

Minuteman

M
e
n
u