Jackson Avenue Pipe, West Side Interceptor, East Side Interceptor, Hallowell Station
What pipes convey influent flow to the WWTP?
It stores flow from the West Side Interceptor
What is the West Side Consolidated Conduit?
Wait for the WSCC to fill and begin discharging to the WWTF before putting this online.
What is Clarifier #3?
The pumps here will shut down on the high flow alarm at the WWTF.
What is Pump Station #2?
The influent end of the HRDT should have a TRC of at least this much
What is 15 mg/L?
Monmouth, Winthrop, Manchester, Hallowell and Augusta
What are the WWTF service areas?
It stores flow from the east side of Augusta
What is the East Side Tank?
If a large storm is forecast, put another one of these online the day before the storm, 100% open, turn rake arm on, enable RAS.
What is another secondary clarifier?
Put these pumps in "hand" during high flow events
What are the grit pumps?
HRDT grab sample test parameters during secondary bypass events
What are E.coli and Total Residual Chlorine?
At 8.0MGD, this gate will close and the influent flow will drop while the WSCC is filling
What is the West Side Interceptor gate?
It stores flow from Pump Station #2 during flows greater than 8MGD
What is Mill Park Conduit?
During high-flow events, leave the RAS rate at this speed
What is 400 gpm?
During disinfection season, make sure the second one of these has come on and we are maintaining an Influent Cl2 residual of approximately 2.0 mg/L
What is the second effluent chlorination pump?
HRDT grab and comp samples must be analyzed when these conditions exist
What is "on days when the plant is normally staffed?"