Heat Pumps and Electric Heat
Electrical Fundamentals
Brazing, Soldering, Welding, and Tubing
Sheet Metal, Ductwork, and Airflow
Computers, Communications, and Workplace Skills
100

Complete this HVAC situation: When wiring a heat pump control circuit an orange wire is commonly used for the O terminal. It controls the

reversing valve coil

100

Respond to this HVAC clue: thermostat differential is temperature

difference

100

tubing cut with a cutting tool is reamed to

removes burrs

100

if the area of a is 1200 square feet and requires 800 CFM, how many CFM will area B require if area B is 300 square feet.

200

100

when filling out the service invoice during a routine preventative maintenance call, the worker should.

record volts and amps

record pressures and temperatures

200

Complete this HVAC statement: An electric furnace that has 10 kW of heat strip will usually have blank sequence steps.

2

200

the main thermostat body includes

the bi metal element

activating mechanisms

internal and external wiring

200

Tubing that has been cut with a hacksaw must be

filed square

200

Give the number of CFM per ton of refrigeration are considered good practice for evaporators of air conditioning.

400

200

A customer has a leak and a 300 ton centrifugal system, refuses to repair the leak, and only requests that you charge the unit. On the service invoice, which of the following needs to be recorded.

the pressures, temperatures, volts, and amps

the amount of refrigerant added in the customer's instructions about not repairing the leak

the customer's name and signature

300

When the emergency heat is energized

the compressor and outdoor fan motor are de- energized 

300

a current relay is easily identified in a schematic drawing because.

contacts and coil are in series

300

The oxygen cylinder used with oxyacetylene heating equipment contains oxygen stored at a pressure of about.

2000 psig

300

The terms IC and IX refer to

tin plate

300

Complete this HVAC situation: when talking to customers

be polite

be punctual

400

The purpose of emergency heat is to

provide heat if the heat pump fails

act as a backup if the house heat loss is greater than the heat pump capacity

400

the result expected of an open start winding in a motor is that the.

overload would open

400

When brazing with oxy Acetylene equipment the Acetylene regulator should never be adjusted to produce any pressure higher than.

15 psig

400

On an insufficient heat call of two rooms, piping or ducts are found running through a cold crawl space under the two rooms. The corrective action would be to.

insulate the piping or ducts

400

most customers prefer a service technician who

maintains personal hygiene

is well groomed

is neatly attired

500

The efficiency of an electric furnace is usually

100%

500

when replacing a start capacitor, a capacitor with a value equal to or within what percent of the original value may be used.

10

500

When lighting a soldering furnace you should

light a piece of paper. place it in the furnace, and then turn on the gas

500

How do you measure ductwork airflow.

CFM

500

A workers first service call for the day was under a house to service an oil furnace. Before proceeding to the next call a thermostat installation the worker should.

change into a clean uniform 