SWITCHES
GYRO SYSTEMS
DATA MULTIPLEXING
SHIPS ORDERING
POWER DISTRO
100

FIRST NUMBER IN A ROTARY SNAP SWITCH DESIGNATION

WHAT IS THE CURRENT RATING OF A ROTARY SNAP SWITCH?

100

SUPPORTING RINGS OF A GYROSCOPE

WHAT IS GIMBALS?

100

DMS IMPROVES INTEGRATION OF THE INTERFACING SHIPS ELECTRICAL SUBSYSTEMS WITHOUT COMPROMISING

WHAT IS TOTAL SYSTEM CAPABILITY?

100

CIRCUIT MB

WHAT IS THE CIRCUIT DESIGNATION FOR THE ENGINE ORDER SYSTEM

100

EMERGENCY SWITCHBOARD SYSTEM IS NORMALLY ENERGIZED FROM..

WHAT IS THE PREFERRED SOURCE OF SHIPS SERVICE POWER?

200

ENABLES THE JR SWITCH TO BE SET TO A DESIRED NUMBER OF POSITIONS.

WHAT IS THE STOP DECK OF A JR SWITCH?

200

PROPERTIES THAT MAKE IT POSSIBLE TO CONVERT A FREE GYROSCOPE INTO A GYROCOMPASS

WHAT IS PRECISION AND RIGIDITY OF PLANE?

200

FIRST STAGE OF MULTIPLEXING ACCOMPLISHED

WHAT IS RM?

200

LOCATION OF TRANSMITTER FOR RUDDER ANGLE INDICATOR SYSTEM

WHAT IS AT THE RUDDER HEAD?

200

PROPER PROCEDURE FOR RIGGING CASUALTY POWER

WHAT IS FROM LOAD TO SOURCE?

300

CONTACTS USED IN JA SWITCHES

WHAT IS SILVER-TO-SILVER?

300

HOW DOES A GYRO REACT TO THE APPLICATION OF TORQUE

WHAT IS MOVE AT RIGHT ANGLES IN THE DIRECTION OF TORQUE?

300

DUAL-STAGE DMS IS SUITABLE FOR

WHAT IS LARGE TO MEDIUM INSTALLATIONS?

300

SHIPS ORDERING CIRCUITS THAT ARE ASSOCIATED WITH THE SHIPS CONTROL CONSOLE

WHAT IS CIRCUIT "M" AND "MB"

300

MOST IC SWITCHBOARDS ARE NORMALLY POWERED BY WHAT POWER SUPPLIES

WHAT IS NORMAL ALTERNATE AND EMERGENCY POWER?

400

VOLTAGE AND AMPERAGE RATINGS OF VARIOUS TOGGLE SWITCHES.

WHAT IS 20 VOLTS TO 600 VOLTS AND 1AMP TO 30AMPS?

400

IF FORCE IS APPLIED TO THE WHEEL OF A SPINNING GYROSCOPE, WHERE WILL THIS FORCE BE FELT

WHAT IS AT A POINT 90 DEGREES AWAY IN THE DIRECTION OF ROTATION?

400

REMOTE MULTIPLEXER (RM) INTERFACE WITH WHAT UNITS

WHAT IS IOU'S AND AM'S

400

CIRCUIT LB

WHAT IS STEERING EMERGENCY ALARM SYSTEM?

400

BUS TIES ON SHIPS SERVICE DISTRIBUTION SWITCHBOARDS SERVE WHAT FUNCTION

WHAT IS PERMIT ANY SWITCHBOARD TO FEED POWER TO ANY OTHER SWITCHBOARD?

500

HOW IS THE LIQUID LEVEL FLOAT SWITCH CHANGED FROM NORMALLY OPEN TO NORMALLY CLOSED

WHAT IS TURNING OVER THE ENCAPSULATED REED SWITCH?

500

ANY FORCE OPERATING THROUGH THE CENTER OF GRAVITY

WHAT IS FORCE OF TRANSLATION?

500

COOLING THE FODMS SYSTEM IS ACCOMPLISHED BY WHAT TYPE OF FAN

WHAT IS AN INTERNAL AC FAN?

500

PERSON WHO OPERATES THE ENGINE ORDER INDICATOR-TRANSMITTERS IN THE SHIPS CONTROL CONSOLE

WHAT IS THE LEE HELMSMAN?

500

THE FUNCTION OF THE ACO SECTION OF THE IC SWITCHBOARD

WHAT IS ISOLATION AND TRANSFER CONTROL OF CERTAIN IC SYSTEMS?

M
e
n
u