Furnaces
Water Heaters
C.O Investigation
Leak Investigation
Appliance inspects
100

it's a temperature activated switch that prevents overheating

What is a high limit?

100

it's the minimum clearance from the front for service

What is 24"

100

This is the level of C.O at which we cannot enter a building

What is 100ppm

100

This is the level where we cannot walk into a building

What is 10%LEL?

100

This is the clearance to combustibles above a residential gas range

What is 36"?

200

It's where I find info on BTU input

What is a rating plate


200

This part is rated for 210 degrees farenheit

What is a Pressure Temperature relief valve

200

The action I take when a customer shows symptoms

What is Call 911?

200

This is the rule we use when evacuating buildings

What is the 10-2-3 rule?

200

this is the clearance to combustible from CPVC Venting

What is 0"

300

it proves that the vent system on on a furnace is working

What is a pressure switch?

300

this is a temperature activated switch that is resettable

What is the E.C.O?

300

At this level I call my supervisor in a workplace

What is 26ppm or higher?

300

This is the level of a class A leak at a fitting indoors

What is less the 5% Gas or 100%LEL

300

This is the minimum clearance the top of the plenum to combustibles

What is 1"

400

It's the measurement from a 60K Btu exhaust termination to a dryer vent

What is 1M or 36"

400

It's the measurement for clearance to combustibles of a B Vent

What is 1"

400

This is who I'm contacting if the levels are higher than 26ppm and there are symptoms

Who is Workplace Health and Safety

400

That's the guy I report to when the fire dept is on scene

Who is the Chief?

400

This the measurement at which electrical wire must be protected

What is 5' from the floor

500

This part removes more heat from the products of combustion

What is a secondary heat exchanger


500

This part helps slow the flue gases as they rise from the water heater

What is a baffle?

500

This is the one thing that triggers us calling 911 everytime

What happens is people are showing symptoms

500

This exempted level of gas reading I can work in for 15 mins to stop the gas leak

What is 50% LEL

500

This is the minimum clearance from a 150K b

BTU furnace exhaust to an HRV intake

What is 10'?