TRUE/FALSE THE LENGTH OF THE CIRCUIT DETERMINES THE BRANCH CIRCUIT RATING.

FALSE IT IS RATED BY THE OVERCURRENT DEVICE

100

OUTDOOR RECEPTACLES ARE REQUIRED TO BE WHAT TYPE?

WEATHER-RESISTANT

100

IN SPIDER-MAN (2002) WHAT NEW YORK CITY NEWSPAPER EMPLOYS PETER PARKER?

THE DAILY BUGLE

100

ACCORDING TO 334.30 CABLE SHOULD BE SUPORTED AND SECURED AT INTERVALS OF WHAT?

4 1/2' 12" (8")

100

TRUE/FALSE GREEN, COPPER/GOLD, SILVER ARE THE 3 COLORS OF THE TERMINALS ON A STANDARD GROUNDING TYPE RECEPTACLE.

FALSE GREEN,GOLD/BRASS,SILVER

200

In NAPOLEON DYNAMITE (2004), WHAT ANIMAL DOES NAPOLEON TELL HIS CLASSMATES HE HUNTED IN ALASKA?

WOLVERINES

200

WHAT IS THE CROSS-SECTIONAL AREA OF THE CONDUCTOR IN CIRCULAR MILLS?

CMA

200

HOW MANY FEET OR LONGER DO HALLSWAY REQUIRE A RECPTACLE?

10

200
WHERE ARE YOU GOING TO FIND BOX FILL CALCLATIONS IN THE CODE BOOK?

314.16

200
GIVE ME THE COLORS AND SIZES OF ROMEX

WHITE 14/2 BLUES 14/3 PURPLE 12/2 YELLOW 12/3

300

TRUE/FALSE WHEN WORKING WITH LOW VOLTAGE YOU CAN CONSIDER YOURSELF SAFE BECAUSE THE VOLTAGE IS THE MOST HARMFUL COMPONENT OF THE CIRCUIT.

FALSE

300

WHAT IS THE LARGEST SIZE SOLID WIRE PERMITTED IN A RACEWAY

10AWG

300

WHAT SIZE BREAKER WOULD YOU USE WITH 8 AWG ROMEX AND WHERE CAN YOU FIND THAT INFORMATION?

40 AMP TABLE 310.16

300

WHAT FILM MAKER MADE THE MOVIES HOUSE OF 1000 CORPSES AND THE DEVILS REJECTS?

ROB ZOMBIE

300

TRUE/FALSE AN IDCI MUST TRIP AT 3-5mA

FALSE 4-6mA

400

WHAT IS THE MINIMUM UNIT LOAD REQUIREMNT FOR DWELLING UNITS IS?

3 VA PER SQFT

400

WHAT ARE THE 3 SIZES OF SCREWS WE USE IN RESIDENTIAL AND WHERE WOULD WE USE EACH ONE?

6/32 DEVICES 8/32 LIGHTING 10/32 CEILING

400

WHAT CAUSES NUISANCE TRIPPING IN GFCIS?

LONG CIRCUIT RUNS

400

EXPLAIN HOW TO WIRE A 3 WAY STATING WHAT WIRE GOES ON WHAT TERMINAL.

HOT/LOAD GOES ON COMMON(BLACK) SCREW AND THE JUMPERS/TAVELERS GO ON THE BRASS. PIGTAIL THE GROUND AND CONNECT TO GREEN GROUNDING SCREW

400

WHAT IS THE NAME OF THE DEPARTMENT STORE BUDDY WORKS FOR IN THE MOVIE ELF?

GIMBELS

500

WHAT SIZE BOX WOULD YOU NEED YO HAVE AMPLE ROOM/VOLUME TO MEET CODE IF YOU HAVE 

(1)3-WAY SWITCH

(1)DIMMER SWITCH

(1)SIGLE POLE

(2)14/3

(4)14/2

3 GANG 45 CU IN

500

IN THE MOVIE TAKEN(2008) WHERE IS BRYAN MILL'S DAUGHTER KIDNAPPED?

PARIS FRANCE

500

YOUR OVERALL SQUARE FOOTAGE IS 5400 INCLUDING 

30'x20' LANAI

32'x12' ATTACHED GARAGE

WHAT IS THE MINIMUM NUMBER OF LIGHTING BRANCH CIRCUITS REQUIRED

8

500

WHAT IS THE VOLTAGE DROP AND WHAT IS THE MINIMUM WIRE SIZE TO INSTALL TO ACCOMPLSH THE 3% DROP.

240-VOLT BRANCH CUIRCUT THE SUPPLISES A RESISTIVE HEATING LOAD OF 15 AMPS. THE DISTANCE IS 100 FT.

7.2V 12AWG

500

WHAT IS THE MAX OPERATING TEMP FOR TW AND THHN IN CELCIUS AND WHAT TABLE IN THE NEC WILL YOU FIND THIS INFO IN?

60 DEGREES 90 DEGREES

TABLE 310.4(1) TABLE 310.16