Low Voltage, High Drama
Not Quite an Electrician
Weak Current, Strong Opinions
LAN Before Time
Where There's Smoke...
100

A detailed description of the work to be performed and the end result expected is a

Work Statement

100

True or False: Small form factor connectors were developed primarily to handle increased bandwidth.

False

100

Unlike BNC, N-type, and RCA connectors, F-connectors do not have what?

A center pin

100

The video cable used in new installations is normally?

RG6

100

A defined area within the boundaries of a fire alarm system is known as a(n)

zone

200

In a DOL-certified apprentice training program, it is necessary to complete a minimum of _____ in each year of the training program.

144 hours of related training and 2,000 hours of OJL

200

The continuity test for twisted-pair cable is most efficiently performed with a

Pair Scanner

200

When connecting wire to equipment, the use of IDC pins eliminates the need to

strip insulation from the wire

200

Label conduit for a campus backbone within _____ of the termination point.

6''

200

Which kind of detector can sense along its entire length?

A line detector

300

An iris scanner is most likely to be installed and serviced by a technician working in the _____ field.

access control

300

Field-fabricated modular cords are not recommended for use with CAT

6 or Higher

300

Backbone cable should be tied and dressed using a minimum bend radius of

10 times the diameter of the cable

300

The MINIMUM size grounding conductor for fiber-optic cable is?

No. 14 AWG

300

Which organization establishes standards for equipment?

NEMA

400

A power fishing system is used primarily to blow or vacuum a _____ through a raceway system.

string line

400

A circumferential crimping tool is used for

coaxial connectors

400

If a manufacturer does not specify a coaxial cable’s bend radius, use a minimum radius equal to

ten times the cable’s diameter

400

Campus straight conduit runs should have pull boxes installed no more than?

140' apart

400

NFPA101 is also known as

Life Safety Code

500

Communication circuits are covered in NEC Article

Article 800

500

The abbreviation IDC stands for

Insulation Displacement Connector

500

A key preliminary termination activity involves

Organizing cable by destination

500

When installing horizontal ER/TR/MC sleeves, a minimum of ___ must be provided between ER/TR/MCs and the horizontal subsystem.

3''

500

Which of the following fires will an IR detector NOT be able to sense?

Alcohol