Hitches
Hardware
Powerline Safety
Slings and Chains
Wire Rope
100

Full rated capacities are based on this hitch.

What is a vertical or straight hitch?

100

The size of a shackle is determined by:

What is the diameter of the body?

100

One of the leading causes of death in the construction industry.

What is electrocution?

100

Safety Factor for chains.

What is 4:1?

100

Wire rope with more wires per strand is more susceptible to wear and easier to_____.

What is bend?

200

Weakest of the 3 main hitches

What is a choker hitch?

200

An equalizer beam can be used as one, but THIS cant be used as an equalizer.

What is a spreader beam?

200

Any part of the crane or load must stay this far away from a powerline up to 350kV.

What is 200 tenths of a foot?

200

Chains must be at least this grade for overhead lifting.

What is 8 or 80?

200

Most wire rope rigging is this type of lay.

What is right regular lay?

300

Strongest hitch

What is the basket hitch?

300

When using wire rope clips the U-bolt must never go over this.

What is the live line?

300

If a crane makes contact with a powerline and cant get away it is important to: 

What is remain in the cab?

300

This is a disadvantage of using chains for lifting

What is limited flexibility, abrasive, heavy, or metal to metal contact?

300

Safety Factor for wire rope

What is 5:1?


400

Minimum size of the load diameter for 1" wire rope slings in a "true" basket.

What is 25"?

400

According to ASME, hook throat openings must not exceed____

What is 5% or 1/4"?

400

If an operator must exit the equipment after powerline contact they should do so in this manner.

What is jump then hop or shuffle away?

400

Chains must be removed when wear of the links becomes this % of the original diameter.

What is 10?

400

The 3 main parts of wire rope are core, wire, and _____.

What is strand?

500

When the horizontal angle is _____ degrees on a 2 legged bridle, the tension in each sling is equal to the load weight

What is 30?

500

Custom designed hardware must be tested to ____% of its rated capacity

What is 125?

500

Minimum clearance must be determined by a registered professional engineer when voltage reaches this level.

What is 1000kV?

500

This chain grade is 50% stronger than grade 80

What is grade 120?

500

Working load limit (WLL) is also known as _____

What is Safe Working Load (SWL)? 

M