Tools
Safety
Air Conditioning
Heating
General Shop/HVAC Knowledge
100

a flat metal tool used for measuring distance

ruler

100

Name the 3 mandatory pieces of PPE necessary for our shop

gloves, glasses, boots/close toed shoes

100

What is the name of the piece of Air Conditioning Equipment typically found out side of the home?

Condenser

100

What does the 90% mean on a 90% furnace?

efficiency

100

In the event of a fire drill, where do we line up out in the parking lot

somewhere between spots 21 and 22

200

a spring-loaded flat coil of steel, kept in a special case that used for measuring distance

tape measure

200

how many students are needed to carry the 6 foot ladder

one

200

What refrigerant is used in the AC Condensers in our shop

R-410a

200

What voltage do the furnaces in our shop run on?

110/115v

200
What safety device must be turned on before soldering

the vent hood

300

We use these snips for cutting thick metal

Blue/Bulldog snips

300

in the event of a spill in the shop, what must be done immediately

clean it up

300

What is the main supply voltage for our AC Condensers?

240v

300

On a gas line, what is the vertical tee with a nipple and a cap called?

Drip Leg

300

What side of a refrigeration system do you connect the red hose to?

high side/liquid side

400

This power too SHOULD be the one you use for putting screws into sheet metal

Impact Driver

400

in the event of an incident/injury what must always be done

report it

400

After a call for cooling, what device energizes first to turn on the condenser

Contactor

400

If a furnace has an input rating of 100,000BTUs and is 90% efficient, what is the furnace output?

90,000

400

This is the part of the ac condenser that expels heat

fan, fan motor, fan blade

500

To hold your work in place while performing a task we use this heavy metal object that utilizes one stationary flat surface and a second, movable surface connected to a large screw. Name it

vice

500

before moving a ladder that was being used for a task, what must be checked?

the top for tools/materials

500

A low refrigerant charge will show as______ superheat

high superheat

500

If you are calling for heat, everything starts up and functions as normal, but you have no gas flow... what should you check first?

The gas valve before the heater, check that you have gas flowing to the heater, see if there is gas in the pipe. 

500

Before turning on the vacuum pump, you must first open this

Gas Ballast