Electrical
Hydraulics
ECS
Fuel/Oil
Propulsion
100

Battery type and volts

Starter Generator volts and amps

24 VDC lead acid batter

28 VDC 300 amps

100

Hydraulic fluid capacity

5 qrts

100

Right and left P3 ports sends bleed air to?

Left = OBOGS, Right = Canopy seal, Anti G, Heating, Pressurization

100

Oil Capacity?

Fuel Capacity (SPR and OTW)?

18.5 quarts

SPR=1100 (530 ea. wing 40 in collector tank) OTW= 1200

100

Name and type of engine

PT6A-68, Free turbine, reverse-flow turboprop 

200

Minimum voltage for Generator to charge the battery

Minimum battery voltage for start

25 Volts

23.5 Volts

200

What does the Hydraulic system operate

Landing gear, main inboard gear doors, flaps, speed brake, NWS


200

1.Bleed air inflow closes automatically when?

2.Cockpit temp is auto controlled from _ to _?

7500 Ft MSL

60-90 degress F (te he)

200

1.Auto fuel balancing keeps fuel lvl with in?

2.Auto fuel balancing turns of when?

keeps fuel lvl in wing tanks within 20 lbs

Turns off when >30 lbs imbalance for 2 minutes 

200

Horsepower and thrust?

flat rated for 1100 shaft horsepower

2750 lbs of thrust at SL zero airspeed

300

What is on the Hot Batt Bus? 

Batt switch, ELT, FDR, OBOGS, Ram Air Valve, Emergency flaps, Clock

300

1.Hydraulic display turns amber when?

2.HYDR FL LO annunciator illuminates when?

<1800psi

<1 quart

300

1. Cockpit is pressurized to what <8000

2. "                 " between 8000-18,069

3. "                 " above 18,069

Ambeint

8000

3.6 +- 0.2

300

1.Red FUEL PX annunciator illuminates when?

2.Amber R/L FUEL LO annunciator illuminates when?

3.Green BOOST PUMP annunciator illuminates when?

<10 psi in motive flow

=to or <110 lbs

Switch on, motive flow <10 psi, starter is activated

300

For what reasons would you abort a start?

Hot start - likely to exceed 1000 c

Hung start- N1 stops increasing

No Start- No ITT with in 10 sec of fuel flow

Batt Bus light- PMU on Batt bus

ST RDY light goes out


400

Items on the AUX Batt 

standby instruments, Lights for standby's, UHF backup radio, FIRE 1

400

EHYD PX LO annunciator illuminates when?

px<2400 +_ 150

400

1.Amber CKPT ALT annuncaitor illuminates when?

2.RED CKPT PX annunciator illuminates if delta p?

Cabin ALT >19,000

3.9-4.0 psi

400

what will not be available with a fuel probe failure?

Auto blancing

DO NOT attempt to manually balance

low fuel warning is still operable

400

3 Components of Gas generation unit?

4 stage axial flow compressor

single stage centrifugal flow compressor

single stage comprssor turbine

500

Dont use External Power when voltage is?

<22.0 Volts

500

Emergency system is pressurized by the _ through a _?


By main system through a one-way check valve

500

1.Amber DUCT TEMP annunciator illuminates if?

2.Amber OBOGS TEMP annunciator illuminates if?

temp is >300 F

temp is >200 F

500

how many probes, where are they, and what do they read to?

7 probes (3 in each wing, 1 in collector tank)

outer probe reads until 445 +- 50 lbs

Middle probe reads until 308+- 50 lbs

Inner probe reads approx 20 lbs

collector probe reads all fuel in tank

500

3 components of Power section

2 stage axial flow power turbine

exhause case

reduction gearbox

M
e