The NEC requires that a(n) ____ be installed at each conductor splice connection point

Box, Outlet Box, Junction Box, JB

100

When making up cord connections on a chain-hung fixture, the conductor with the grooved or raised insulation is the ____ conductor

Grounded

100

A device's primary function is to ____.

Utilize electrical energy.

100

An area with a sink and permanent provisions for food preperation and cooking

Kitchen

100

S1

Single Pole

200

According to ____, unused knockouts and other openings in electrical boxes and cabinets are required to be closed.

110.12(A)

200

Leaving fluorescent lamps on for long periods of time ____ lamp life.

Extends

200

. Device faceplates must be mounted so as to ____.

cover the opening in the wall and to seat against the wall surface

200

As defined in NEC Article 100, a(n) ____ is a point on the wiring system at which current is taken to supply utilization equipment

Outlet

200

S3

Three-Way

300

Where noncombustible surface material is used on walls or ceilings, outlet boxes must be mounted so that they will be set back not more than ____ from the face of the surface material.

1/4"

300

A T12 fluorescent lamp is ____ inch(es) in diameter and a T8 is ____ inch(es).

1-1/2, 1

300

Class A GFCI devices may or may not trip (open) when a ground-fault in the range of ____ milliamperes occurs.

4-6

300

A contact device installed at the outlet for the connection of an attachment plug.

Receptacle

300

S4

Four-Way

400

In order that the connections inside an outlet box remain accessible, the NEC requires that a surface extension from an outlet box cover be made using ____.

Flexible Connections

400

Recessed lighting fixtures constructed for installation in thermal insulation are rated as ____.

Type IC

400

NEC 406.4(D)(4) requires ____ protection where replacements are made at receptacle outlets that are required to be so protected elsewhere in the Code.

Arc Fault

400

Location protected from weather and not subject to saturation with water or other liquids, but subject to moderate degrees of moisture

Damp Location

400

A circle with an R in the middle.

Recessed Fixture

500

. The NEC requires that when a suspended ceiling grid is used to support lay-in type lighting fixtures, ____.

the grid be securely fastened together and secured to the building structure and the lay-in fixtures be securely fastened to the grid members using bolts, screws, rivets, or listed clips

500

Fluorescent lamps are color-rated in terms of Kelvin degrees. The ____ the Kelvin degrees, the ____ the color tone

Higher; Cooler

Lower; Warmer

500

Electrical wall boxes should not be mounted back-to-back in walls because ____.

Fire, Sound, Smoke, Building Codes.

500

One who has the skills and knowledge related to the construction and operation of electrical equipment and installations and has received safety training to recognize and avoid the hazards involved

Qualified Person

500

A solid line from and electrical symbol with an arrow.

Home Run