SAR
Ventilation
Fire Hose
Hose operations
Fire suppression
100

What does LUNAR mean?

L- Location

U- Unit

N- Name

A- Air/Assignment

R- Resources needed

100

What roof type are spongy roofs usually associated with

Flat roofs but can also apply to pitched roof

100

Two-way non-threaded couplings come in 2 varietys, what are they?

Storz and Quarter-turn

100

Hydrant discharge outlets are considered standard if they contain the following two components:

at least one large (4 or 4.5 inch) outlet 

two hose outlet nozzles for 2.5 couplings

100

What is the attack on the actual fire using a solid or straight stream 

Direct Attack

200

How many firefighters needed for VEIS when using a ladder?

Minimum of 3. 

One firefighter to heel the ladder, one operating on the ladder in contact with FF, and one inside completing VEIS.

200

How does PPV work?

Artificially raising the pressure inside the structure so that smoke and fuel gasses move toward lower pressure openings more quickly

200

When should hose be inspected per NFPA 1962?

Within 90 days after purchase before placing in service and annually 

200

What are two common mobile water supply operations?

Water shuttle and relay pumping

200

Attack made from inside or outside the structure directing the stream toward the ceiling to cool the room or banking the stream off the walls.

Indirect Attack

300

What are reasons to call a MAYDAY?

Air emergencies, lost/disoriented, entanglement, rapid fire development, collapse/trapped

300

How many firefighters at least are needed for Vertical Ventilation?

At least two but with no more personnel than absolutely necessary 

300

Roll commonly used when hose is to be deployed for use directly from roll

Donut roll

300

What are some examples of static water supply sources?

Lakes, Ponds, Rivers, Swimming Pools, Portable water tanks

300

Attack in which you use Z, T or O to combine cooling the gasses above the fire and fuels on the floor

Combination Attack

400

What are reasons an air monitor might not give an accurate reading?

Incorrect use

Poor Calibration

Low battery power

400

What cut is made when the truss is in the middle of the opening?

Louver Cut

400

What are the most commonly used lines that most fire departments use for attack lines?

Preconnects

400

What is attached to either end of a hard suction hose?

One end to the pump, other end to the strainer

400

Has a yoke on the outside with a threaded screw that opens and closes the gate inside the valve housing. The threaded portion of the screw is visible beyond the yoke only when the valve is open.

Outside screw and yoke (OS&Y) valve

500

What are limitations of TICs

Cannot see through glass or reflective surfaces

Cannot detect if a person is under or behind furniture

May not be able to detect fire on floors below if floor is carpeted

500

What is the purpose of a trench cut?

To create defensible line ahead of the fire's spread. Usually ordered when the main body of the fire is too large to extinguish.

500

Hose load folded in three layers then laid in to the bed in an S-shaped fashion. Designed for one person to pull.

Triple Layer Load

500

What can be used to transfer water from one portable tank to another portable tank?

Jet Siphon

500

Has a hollow metal post that houses the valve stem. Has a movable plate with the words OPEN and SHUT visible through a small glass window on the side of the housing.

Post-indicator Valve (PIV)