Electrical Safety
Chap 4
Electrical Chap 1-3
Electrical 5-6
100

How hot can an arc flash be

35000 degrees 

100

The receptacle outlet for servicing air conditioning equipment is required to be located on the same level as the HVAC equipment and within ____ feet of the equipment.

25

100

In the metric system, what is the prefix for 1000?

kilo

100

Type MC cable is a factory assembly of one or more insulated circuit conductors with or without optical fiber members enclosed in an armor of ____ metal tape, or a smooth or corrugated metallic sheath.

interlocking

200

OSHA has recognized a number of organizations that meet the legal requirements in OSHA 29 CFR 1910.7. What is the industry acronym for these organizations? 

A. NRTL                             C. QETL

B. USMCA                          D. NAFTA

A. NRTL

200

When sizing conductors and overcurrent protection, you must take 100% of the non-continuous loads plus ____ of the continuous loads.

125%

200

What is the metric designator for a raceway of trade size 3?

78

200

When a box contains fittings, such as luminaire studs, clamps, or hickeys, the number of conductors permitted in the box is one less for ____ fitting.

each type of

300

In the areas where ____ is enforced, the NEC® is the law.

OSHA

300

For motors, the OCPDs are ____.

inverse-time circuit breakers

300

The total voltage drop in the combined feeder and branch circuits should not exceed ____ percent.

5%

300

Due to repeated failures, a rule has been added in NEC _____ that, where HVAC equipment is installed on a roof, an equipment grounding conductor of the wire type must be installed in outdoor portions of metal raceway systems that use compression-type fittings.

NEC 440.9

400

Pressures developed during an arc blast can be as high as ______ pounds per square foot.

2160

400

The unit values of NEC ____________ are based on minimum load conditions and ___ power factor and might not provide sufficient capacity for the installation contemplated.

Table 220.42(A); 80%

400

The purpose of the National Electrical Code (NEC)® is the practical safeguarding of ____ from hazards arising from the use of electricity.

persons and property

400

Drain holes not larger than ____ in diameter are permitted to be drilled at appropriate locations in conduit bodies, such as LBs, or in wet-location enclosures. Properly installed drain holes or fittings will help prevent water from entering enclosures that contain energized parts that can be damaged by exposure to water.

 ¼ of an inch

500

The amount of heat in an arc flash will instantly vaporize copper and expand it ______ times its original volume.

64000

500

Multioutlet branch-circuit ratings are limited to 15-, 20-, 30-, 40-, and 50-ampere except on ____ premises, where they may have a higher rating 

industrial

500

For equipment rated at 100 amperes or less, the allowable ampacity values found in the ____ column of NEC® Table 310.16 are generally to be used.

60 degrees C

500

In commercial buildings, ____ protection is required for all 125-volt through 250-volt receptacles supplied by single-phase branch circuits rated 150 volts or less to ground, 50 amperes or less, and all receptacles supplied by three-phase branch circuits rated 150 volts or less to ground, 100 amperes or less, installed in bathrooms, in kitchens, on rooftops, outdoors, within 6 ft (1.8 m) from the outside edge of any sink, in indoor wet locations, in locker rooms with adjacent shower facilities, and garages, bays, and similar areas.

GFCI