Without Exceptions. The means of egress shall have a ceiling height of not less than?
What is 7 foot 6 inches.
1003.2 Ceiling Height
A limited area sprinkler system shall not exceed __ sprinklers in any single fire area.
What is 6.
903.3.8.1 Number of Sprinklers
Persons shall not keep or store, nor shall any permit be issued to keep or store, any explosives at any place of habitation, or with in ___ feet thereof?
What is 100 feet
5601.2.1 Residential uses
The fire code official is authorized to grant, in writing, one or more extensions of the time period of a permit for periods of not more than ___ days each.
What is 180 Days.
105.3.2 Extensions of operational permits
Name the 3 Committees listed in the Law and Admin code book under Committees.
What is:
1.Standing Committee
2. Ad Hoc Committee
3. Hearing Committee
202.8 Committees (Law and Admin)
Without Exceptions. What is the stair riser heights maximum and minimum?
What is 7 and 4 inches.
1011.5.2 Riser height and tread depth
Portable fire extinguishers shall be provided within a __ -foot distance of travel from a commercial-type cooking equipment?
What is 30 Feet
904.12.5 Portable fire extinguishers for commercial cooking equipment.
The number of cylinders contained in a single gas cabinet shall not exceed ___.
What is 3.
5003.8.6.3 Maximum number of cylinders per gas cabinet.
Without exceptions. What is the permitted amount for a liquid corrosive material
What is 55 gallons
Table 105.6.21
Vaults and their tanks shall be suitably anchored to withstand uplifting by ______ _______ or _______, including when the tank is empty.
What is Ground water or flooding
5704.2.8.5 Anchoring
******DAILY DOUBLE******
What is the occupant load factor for Exercise rooms with and without equipment?
What is 35 net and 50 gross
Table 1004.1.2
Without exceptions. A manual actuation device shall be located at or near a _____ __ ______ from the cooking area not less than __ft and not more than __ ft. from the kitchen exhaust system.
What is means of egress, 10 feet and 20 feet.
904.12.1 Manual system operations
The emergency disconnect switch for exterior fuel dispensers shall be located within ____ ft, but not less than __ ft from, the fuel dispensers.
What is 100 feet and 20 feet.
2303.2 Emergency dis connect switches.
All drawings and specification requirements shall be drawn to scale with sufficient clarity and detail to indicate the nature and character of the work and shall accompany the application permit . All information, drawings, specifications and accompanying data shall bear what information?
What is: Name, address and signature of the person responsible for the design
106.2 Drawings and specifications (Law and Admin)
Tents or membrane structures shall not be located within __ feet of lot lines, buildings, other tents or membrane structures, parked vehicles or internal combustible engines
What is 20
3103.8.2 locations
The force of pushing an interior door open other than fire doors shall not exceed ___lbs? For other swinging, sliding and folding doors the latch shall release when subjected to ___lbs? The door shall be set in motion when subject to ____lbs?
What is 5, 15 and 30 pounds of force
1010.1.3 Door Opening Force
******DAILY DOUBLE*******
Where hazard areas include deep fat fryers, what number of 80 lb. fryers are covered by (1) 1.5 K portable fire extinguishers?
(1) 1.5 K Extinguisher for every 4 fryers
904.12.5.2 Class K portable fire extinguishers for deep fat fryer. Exception 1
Persons shall not construct a retail display nor offer for sale explosives, explosive materials or fire works upon ________, _________,_________, or in Group __ or __ occupancies.
What is a highway,sidewalks,public property and groups A or E
5601.2.2 Sale and retail display
Name 1 occupancy type per classifications
A-1,A-2,A-3,A-4, and A-5?.
Refer to Judge Miller
Reference code section 203 pg. 41.
******** DAILY DOUBLE ***********
In Log Storage areas, cold decks shall not exceed ___ feet in length, __ feet in width, and __ feet in height. Cold decks shall be separated from adjacent cold decks or other exposures by not less than __ feet.
What is 500, 300, 20, 100
2806.2 cold decks
Without Exceptions. What is the maximum and minimum width of the solid and continuous stripe on the steps of high rise egress stairwells?
What is 1 and 2 inches.
1025.2.1 Steps
Automatic equipment interlocks with what 7 listed items
What is fuel shutoff, ventilation controls, door closures, window shutters, conveyor openings, smoke and heat vents.
904.3.3 System Interlocking
Above ground outside storage tanks exceeding an aggregate quantity of _____gallons of corrosive liquids shall be provided with _______ ________.
What is 1,000 gallons and secondary containment.
5404.2.1 Above-ground outside storage tanks
*****DAILY DOUBLE******
The provision of this code shall not apply to what 6 of following:
What is:
1. 1 and 2 family dwellings
2. Farm buildings
3. Storing handling and transport of LP gases
4. Design, construction, location and installation of public utilities
5. Substances governed by Hazardous Chemicals Right to Know Act
6. Open burning under jurisdiction of the NC Department of Agriculture and Consumer Services
102.13 Exception to Applicability
In high-piled combustible storage: Without exceptions, Dead-end aisles shall not exceed __ feet in length in Group M occupancies. Dead-end aisles shall not exceed __ feet in length in all other occupancies
What is 20 feet, and 50 feet.
3206.9.3 Dead-end aisles