100

What do the dotted lines and crosshatched areas on a damage control diagram indicate

What is Hidden boundaries

100

How should primary fire boundaries be set

A primary boundary is set using the bulkheads, deck, and overhead closest to and surrounding the fire

100

What are the two types of Navy Firefighting nozzles used onboard ships

What is All Purpose and VARI

100

The Navy uses SCBA bottles with a rated duration of ....... or ....... minutes.

What is 30, 45

100

What is the shape of the contamination marker

What is triangle

200

Laminated copies of ship's diagrams are used to .......

What is chart the status and progress of damage control emergencies or drills

200

Who sets and maintains the boundaries, and removes and relocates flammables

What is Boundary man

200

What type of nozzle is at the fireplug station

What is Vari-Nozzle

200

What is the purpose of the OCENCO EEBD

What is Escape smoke or toxic atmospheres

200

The distance of a ship's keel to the waterline is indicated by ....... draft marks

What is Calculating

300

What do the heavy lines on DC Diagrams indicate

What is watertight and airtight boundaries

300

How often do investigators rove an assigned area

What is continuously rove an assigned area

300

What are the spray patterns for the VARI-Nozzle

What is Straight stream, Narrow and Wide angle fog

300

How long will the OCENCO EEBD operate after it is activated

What is 10 minutes

300

Contamination control marking signs are .......

What is 11-1/2 inches by 8 inches by 8 inches.

400

In the event that Damage Control Central is lost due to battle damage, which repair party would assume the duties as back up Damage Control Central

What is most remote repair locker

400

Who searches the surrounding area for fire, damage, and personnel casualties

What is Investigator

400

What is the bail position and spray pattern setting for the VARI nozzle located at a fire station

What is Forward (SHUT) and high velocity fog (NARROW V)

400

How should you test the SCBA face mask for a seal

What is perform a seal check by placing palm of hand over adapter port on facepiece, inhale and hold breath for a second so facepiece can seal to face

400

How many complete air changes are required to remove 99% of airborne contaminants

What is 6

500

The color yellow indicates ....... on a DC diagram.

What is DC repair stations and DC Central

500

What is the purpose of the Naval Firefighters Thermal Imager

What is to see through light smoke and dense steam

500

What is the total length of three standard lengths of fire hose connected together

What is 150 feet

500

Which of the following contain the proper procedures for donning the OCENCO EEBD

What is remove EEBD from case, insert mouthpiece, attach nose clip, inhale and escape

500

The SCBA Bell Alarm will provide an audible warning when cylinder air pressure falls below ....... percent of cylinder capacity

What is 25