Luminaires & Lighting
Branch Circuits
Receptacles
Conduit
Grounding and Bonding
100


1 points


Paddle fans over _____ must be supported independently of the box:

what is 70 lbs

100





A branch circuit for an appliance that’s a continuous load must be rated not less than _____ of the marked ampere ratings of the appliance:

which is 125%

100





Receptacles not supplying loads directly related to circulation systems must be located not less than _____ from the inside walls of the pool:

what is 6ft

100




Flexible Metal Conduit (FMC) must be secured within _____ of each box, cabinet, conduit body or other termination:

what is 12in

100





The portion of the grounding electrode conductor that is the sole connection to one or more ground rod is not required to be larger than _____:

what is 6 awg

200




The minimum lighting load for industrial commercial buildings is _____ volt amperes per square foot:

what is 2.2 or 2

200




The conductors between the service equipment, a separately derived system, or other power supply and the final branch circuit overcurrent device:

What is a feeder

200






Receptacles located more than _____ above the floor are not required to be tamper resistant:

which is 5.5 ft

200






The maximum approval electrical trade size of IMC is ________ :

 which is 4 in

200





If multiple power sources supply portable structures, the circuit equipment grounding conductors at each portable structures must be bonded together for all portable structures separated by less than ____:

what is 12ft

300





A vertically mounted luminaire weighting no more than ______ can be supported to a device box or plaster ring secured to a device box:

which is 6 lbs

300






An electric heater having a capacity of _____ gallons or less is considered as continuous load for the purpose of sizing branch circuits:

what is 120 gal

300





Receptacles located more than ______ from the wall or room divider may not be counted as required receptacles:

what is 18 in

300





RMC is not required to be securely fastened within _____ of the service head for an above the floor termination of a mast:

what is 3ft
300






Separately derived systems rated ______ or less are not required to be grounded:

what is 1 KVA

400





A luminaire supported by a single conduit shall not exceed ______ in any horizontal direction from the point of conduit entry:

what is 12 in

400





Branch circuit conductors for information technology equipment must have an ampacity not less than _____ of the total load connected:

what is 125%

400





Single receptacles that provide shore power for boats must be rated not less than ____:


what is 30 A

400





In building over 3 floors. ENT must be concealed behind floors, walls, or ceiling that have a _____ minute finish rating:

which is 15 mins

400





The supplemental electrode for a rod electrode must be installed not less than _____ from the rod electrode:

What is 6ft

500





Conductors within ______ of ballast, LED driver, power supply or transformer must have an insulation temperature rating not lower than 90oC

which is 3 in

500





The branch circuit VA load for heavy duty lampholders must be calculated at a minimum of ______ :

what is 600 VA

500





All _____ 125V receptacles installed in locker rooms with associated showering facilities must be GFCI protected:

what is 15 and 20 A

500





LFNC must be securely fastened within an interval not exceeding _______:


what is 3 ft

500





Insulated equipment grounding conductors _____ and larger can be permanently reidentified at the time of installation at every point where the conductor is accessible:

what is 4 AWG