The measure of the color appearance of a light source which helps describe the apparent 'warmth' or 'coolness' of the light source is called __________
Temperature
The most common receptacle type used in residential wiring is the _________
Duplex Receptacle
A GFCI device provides protection against __________.
Ground faults
This article states all work must be done in a neat and workmanlike manner
110.12
If the two conductors to be connected to a single-pole switch are black and a re-identified white, the connection you are using is called a(n) _________________________
Switch Loop
What do the letters “LED” stand for?
Light Emitting Diode
When a duplex receptacle is installed horizontally, it is recommended that the __________ slot be located on top.
Grounded
Arc Faults
Installation requirements for light fixtures are contained in Article __________ of the NEC
410
The NEC defines a(n) ____________________ as a contact device installed at an outlet for the connection of an attachment plug.
Receptacle
____________________ lamps are referred to as 'electric discharge lamps' by the NEC
Flourescent
A __________ receptacle is one that has internal shutters that are closed behind the receptacle slots when there is no attachment plug inserted. The shutters open when a plug is inserted allowing the plug (and cord) to become energized
Tamper Resistant
Who was the founder of the incandescent "Light Bulb"
Thomas Edison
Section _______ in the NEC® requires all of the 15- and 20-amp, 120-volt branch circuits installed in dwelling unit kitchens, family rooms, dining rooms, living rooms, parlors, libraries, dens, bedrooms, sun rooms, recreation rooms, closets, hallways, laundry areas, or similar rooms or areas to be AFCI protected.
210.12(A)
A __________ is defined by the NEC as a complete lighting unit consisting of a lamp or lamps together with the parts designed to distribute the light, to position and protect the lamps and ballast, and to connect the lamps to the power supply
Luminaire
Lamp diameters are measured in __________ of an inch
8ths
If a device box has been installed too far back behind a wall, a __________ can be used to bring the edge of the box flush with the wall surface
GFCI's should be tested once per ______
Month
Article _______ specifies that screws used for attaching a SWITCH to an electrical box must be machine screws with 32 threads per inch
404.10(B)
Locations protected from weather and not subject to saturation with water or other liquids but subject to moderate degrees of moisture.
Damp Locations
Lamp ________is a ratio of the number of lumens a lamp produces to each watt of power it uses
Efficacy
The proper NEMA designation for a 30 amp, 125/250 volt grounding type receptacle installed for an electric clothes dryer is __________.
14-30R
All equipment installed per the NEC must be _________
Listed
A luminaire that is cord connected or chain-, cable- or cord-suspended cannot have any part of the fixture within a zone measuring __________ feet horizontally and __________ feet vertically from the top of the bathtub rim or from a shower stall threshold
3; 8;
A duplex receptacle that is wired so one half is hot all the time and the other half is switch-controlled is called a(n) ____________________ receptacle
Split Wired