Core
TYPE 1
TYPE 2
TYPE 3
Dates
100

An ozone molecule is made up of....

What is 3 oxygen molecules  

100

EPA section 608 certification must be renewed every how many years

What is none

100

Pressure relief valves must not be (in series, parallel, vertically, horizontally)

What is in series

100

After recovering the liquid refrigerant what must then be recovered

What is vapor refrigerant

100

Halons were completely phased out by what year

What is 1994

200

A refillable refrigerant cylinder must never be filled more than what percent of its capacity by weight

What is 80%

200

A drop in replacement refrigerant substitute for R-12 in a small appliance

What is none

200

The evaporation temperature of R-410a at 100 psig is

What is 30 degrees

200

During chiller evacuation water is circulated to prevent

What is freezing of water

200

If using a recovery machine after this date you must evacuate the unit to 0 psig

What is November 15, 1993

300

Blended refrigerants leak from a system in uneven amounts due to different

What is vapor pressures

300

What is the maximum allowable factory charge of refrigerant for Type I appliances?

5lbs

300

When under a deep vacuum the motor winding of a hermetic refrigeration compressor will be damaged if

What is energized

300

Maximum test pressure for a leak testing a low pressure centrifugal how many psig

What is 10

300

when was the Montreal protocol put in place 

September 16th, 1987

400

Refrigerant that enters the expansion of throttling device is in what state of matter

What is liquid

400

At high temperatures (for example open flames and glowing metal surfaces) R-12 and R-22 can decompose to form

phosgene gas

400

When inspecting a system for leaks one of the first things to leak for

What is traces of oil

400

The PRIMARY purpose of a purge unit on a CFC-11 chiller is to remove

What is noncondensables

400

Recovery equipment used for the service or repair of small appliances must be certified by an EPA-approved laboratory if the recovery equipment was manufactured after

 November 15 1993

500

When using nitrogen to pressurize a system you should always charge through a...

What is pressure regulator

500

When using a passive system dependent recovery process you should access both the high and low side of the system for the refrigerant recovery if

What is the compressor does not run

500

A system can be evacuated to only atmospheric pressure when leaks in the appliance...

What is make evacuation to the prescribed level unattainable

500

What should Mr.Varley get the class for breakfast?

 What is Breakfeast Sandwhich

500

When using recovery and recycling equipment before this date technicians must evacuate a unit that has 10lb charge of CFC-500 to 4 inches of Hg vacuum

What is November 15, 1993

M
e
n
u