Due to their impact on the environment, most refrigerants are now regulated by either the ____________________________, ____________________, or both.

What is EPA, state laws



100

n air conditioning applications, the industry standard for airflow across the evaporator is _____ cubic feet per minute (CFM), per ton of cooling.

what is 400 cfm

100

With proper ventilation on a jobsite or work area, flammable refrigerants can be kept below their ______________________________ should a leak occur. 


What is `lower flammability limit`

100

A2L systems are designed with electrical components that are


What is `intrinsically safe (IS).`

100

Refrigerants that have a lower-case letter designation indicate





What is an isomer. 


200

Most compressors require _________________ to operate properly, which is specified by the manufacturer.

What is `lubrication (oil)` 

200

A(n) ______________________________ designation is used when refrigerant blends are composed of the same refrigerants, but with different percentages of each.

What is uppercase

200

The_________________________ is the minimum electrical spark energy, in millijoules (mJ), required to ignite a flammable gas/air mixture.


What is `minimum ignition energy (MIE)`

200

For evacuation, some manufacturers of A2L equipment require that the system be 


What is `triple evacuated`

200
If different refrigerant types are mixed in the same tank, the mixture may not be able to be recycled or reclaimed and may have to be;




What is destroyed at the owner’s expense.


300

The two types or classes of metering devices are _________________ and ______________________.

What is fixed and adjustable` 

300

ASHRAE Standard ________ is used to classify a refrigerant according to the potential hazards involved with its use, specifically toxicity and flammability.

What is 34

300

What is a measurement of the amount of heat released when a substance, in this case, a refrigerant, burns.


What is `Heat of combustion (HOC)`

300

When charging an A2L system where ventilation mitigation has been installed, the maximum allowable charge cannot exceed the  

What is `m2`charge weight.


300
Small amounts of moisture can react with the refrigerant and oil in the system causing the formation of;



What is acid.


400

Additional components that may be installed on the low side of a refrigeration circuit are ____________________ and _____________________.

What is accumulator and suction line drier`

400

Refrigerants that have a lowercase letter (a, b, c) designation indicate a(n) _____________________.

What is Isomer

400

When fluorinated refrigerants decompose, they can also form a short-lived gas called 


What is `carbonyl fluoride, COF2`

400

components such as the contactor or capacitor are designed to be enclosed, isolating the electrical contacts from the atmosphere


What is `Intrinsically safe`

400

Which of the following must be recorded on the label of A2L equipment upon completion of installation?

What is Dates that the pressure test and evacuation were completed. 

500

R-404A has a global warming potential (GWP) of _____________.


What is `3920`

500

What occurs when one or more of the refrigerants in a blend leak at a faster rate than other refrigerants in the blend.

What is Fractionation 

500

R-1234yf has an MIE of 


What is `5,000-10,000`

500

For A2L-charged systems, the maximum allowable charge is not 


What is `a universal figure`

500

When working with A2L refrigerants: what is not an approved leak detection method?

What is Halide Leak Detector 