1
2
3
4
5
100

This measurement is typically stamped on nonmetallic electrical boxes.

What is the internal volume?

100

Most ICC-adopted codes require this around electrical conduits.

What is firestopping?

100

Kitchens, bathrooms, and laundry rooms are examples of areas where these are often specified.

hat are specific receptacle and switch heights?

100

NEC requires boxes with internal volumes of this size or less to be marked with cubic-inch capacity.

What is 100 cubic inches?

100

Architects and engineers may use different ones of these, so verification is important.

What are symbols?

200

According to code, this is the maximum permitted gap between a box and the wall material.

What is β…› inch?

200

Receptacles installed between the backsplash and cabinets in kitchens are typically mounted at this height.

What is 44–46 inches?

200

With noncombustible surfaces, boxes must be set back no more than this distance from the finished surface.

What is ΒΌ inch?

200

After cutting the proper opening, one acceptable method is to use boxes with these features.

What are plaster ears?

200

some curved lines indicate the electrical connection or this aspect of receptacles.

What is circuiting?

300

Installing electrical wall boxes back-to-back in the same stud space can do this to a wall or ceiling.

What is defeat the fire-resistance rating?

300

This is the standard mounting height range for receptacles on walls.

What is 12–18 inches?

300

When combustible surface material is used, boxes must be installed this way.

What is flush with the surface material?

300

Manufacturers typically provide these in boxes so luminaires can be attached.

What are tapped holes?

300

Along with conductor size and splices, these affect the choice of electrical boxes.

What are clamps or fittings?

400

When nonmetallic boxes are permitted, the manufacturer must provide this information.

What is the box volume?

400

Ceiling outlet boxes used only for lighting must support at least this amount of weight.

What is 50 pounds?

400

Standard 6-32 screws used on device boxes correspond to this thread description.

What is 0.138-inch diameter, coarse pitch?

400

An electrician must do this to plans and also do this mentally to coordinate views.

What are convert and visualize?

400

Ceiling outlet boxes in habitable rooms must be framed, marked, or this to support potential ceiling fans.

  1. What is listed for the required weight?

500

To reduce confusion with structural components, electrical wiring is shown on plans using these types of lines.

What are curved lines?

500

You must be careful interpreting electrical symbols because of this shared characteristic.

What is similarity?

500

Curved electrical lines help distinguish circuitry from drawing lines used in this discipline.

What is building construction?

500

NEC 314.16 requires boxes to provide this for conductors without crowding.

What is ample room?

500

when calculating conductor fill in a metallic box with different conductor sizes, you must add all applicable volumes and then reference this NEC table.

what is Table 314.16(A)