Shake Flask Operations
50L Bioreactor Operations
500L Bioreactor Operations
2K Bioreactor Operations
GDP/GMP
100

What is the amount of days of cultivation for Passage 3?

3

100

True/False. When additional material is needed for 50L operation, a note is required in the batch record. 

True. 

100

What is the item number for the Levitronix pump chamber?

Item # 8120

100

True/False. The inoculation target volume is calculated by the inoculation recipe in MPCS.

False. The inoculation target volume is calculated by operators.

100

True/False. The correct shorthand code for a time error is "TE."

False. There is no shorthand code for a time error. "TE" should be used for a transcription error.

200

What is the volume of media required to warm for Passage 2?

50.0mL +/- 0.5mL 

200

The following scenario is correct: NOVA pH: 7.01 Controlling probe: 7.03, Non-controlling probe: 7.08 Correct both probes to the NOVA pH.

No it is not correct. No correction to the controlling probe. Correct the non-controlling probe to match the controlling probe.

200

Find the error in the following statement: Person A recorded the NOVA metabolites in the batch record. They record "N/A" for the Lactate. Person B verifies. Both operators proceed to the next step. 

Operators should have contacted MS&T and collected a non-routine sample. A footnote should have been made in the corresponding step. 

200

What is the governing TD for Tsuru control strategy?

TD21865

200

What is the SOP governing Good Documentation Practices?

SOP-0028

300

What is the SOP governing Shake Flask operations?

SOP-2262

300

What is the document number of the 50L bioreactor operation?

BR-1850

300

True/False. The operators taking the daily sample must be the same operator to record the date/time. 

False. The operator taking the daily sample is not the operator recording the date/time.

300

True/False. The time window to submit a supernatant sample to sample coordination is 4 hours. 

True.

300

What is wrong with the following correction? Person A records 1.58 but the Batch Record states the number of decimals is one. Person A then crosses out the number and corrects it to 1.6 and makes a footnote stating "RE."


"RE" is not a valid shorthand code. The correct footnote should state "rounding error."

400

True/False. The shake flask cannot be moved into the incubator while Vi-Cell results are being obtained. 

False. The shake flask can be moved into the incubator while the Vi-Cell results are being obtained.

400

True/False. Potassium (K+) and Calcium (Ca++) are required metabolites for daily samples.

False. Potassium (K+) and Calcium (Ca++) are not required metabolites for daily samples. 

400

What value are the DO probes spanned to prior to inoculation?

760.00 mmHg

400

What value must the Glucose fall under to require a Glucose bolus?

2.00 g/L

400

True/False. Both date formats are correct: 22Mar2026 and 22March2026

True.

500

What is the minimum volume of air that needs to be sampled before stopping environmental monitoring?

1m3

500

What is the value in the following PO2 calculation:

149.3 mmHg ÷ (x) mmHg = 93.9%

1.59

500

What is the media equilibration duration?

12 - 36 hours

500

What is the allowable response period for pH?

30 minutes

500

True/False. The use of slashes or hyphens (ex: Ø) are not permitted. 

False. The use of slashes or hyphens are permitted.