A free standing Electric range having an ampacity not more then 50A shall be connected to what size breaker
What is 40A
14/2 NMD must be secured within how many mm of a device box
what is 300mm
Wire size for a 100A circuit ( copper)
What is#3awg
What is the recommended depth of discharge for lead acid batteries
what is 50%
what is a plumbers fav food
The term used to identify the wire terminating to the black screw of a 3 way switch
What is the Common
Number of receptacles required for an unfinished basement
What is 1
device used to keep weather out of the service mast
What is a weatherhead
In an led the anode is the _________lead
what is positive
Jason's favourite code book section
What is section 12
What colour is the sheathing of 12/2 NMD used in kitchen plug circuits
What is yellow
Minimum size of copper grounding conductor
whats #6awg
minimum length of service conductors beyond the mast
what is 750mm
maximum degree of bends allowed in a run of conduit.
what is 360 degrees
Your leads must be in _____ with the load when measuring current using a DMM.
what is series
minimum amount of conductor inside a device box (in mm)
what is 150mm
minimum burial depth for a raceway in a non-vehicular area
what is 18" (450mm)
minimum trade size of service mast
what is 63
maximum spacing for trade size 21 pvc conduit
what is 750mm
value of a 3 band resistor RED,BLACK,BLACK
what is 20 ohms
A pair of marettes count towards boxfill, they are equal to_______?
1 insulated conductor of the largest size in the box
The most common termination temperature of devices.
what is 75 degrees.
what must be removed when installing a sub panel
what is a bond-neutral connection
a series circuit with 3 100ohm resistors and a total current of .5A, what is the current at R2 and the applied voltage
what is .5A and 150V
first 2 colours of b standard wiring for RJ45 connectors
What is orange white, orange