REFRIGERANT
Electrical
Hiller
Pulling a vacuum
WILDCARD
100

This component will lower the pressure and temperature in the refrigerant cycle

Metering device

100

This component is responsible for converting alternating current to direct current.

An inverter

100

What is our core value?

CARE

100

What is considered a deep vacuum?

Below 500 microns

100

Who invented modern day air conditioning?

Willis Carrier

200
What should your LSAT be on a 10 seer system on a 90 degree day?

115-120 degrees

200

This tool is used to measure air velocity

Anemometer 

200

What would be the cost for an HHC membership for a customer with five systems?

50 dollars a month

200

Why are decay tests important?

To ensure that no moisture or leaks are present in the system

200

What does a hydronic system circulate?

Water

300

Why do gauges show PSIG instead of PSI?

PSIG stands for pounds per square inch gauge. Refrigerant gauges don't account for atmospheric pressure (14.7 psi)

300

When a system is not coming on, this component is the thing we check


The thermostat

300

What is this month's HVAC promotions for HHC customers?

25% off on repairs and up to $1500 off replacements

300

What level of microns is atmospheric pressure at sea level?

14,700 microns

300

What does the term "one ton of refrigeration" come from?

The amount of heat required to melt on ton (2,000 pounds) of ice over a 24-hour period 

400

What will cause a high delta t?

Evaporator malfunction or low air flow

400

You measure the resistance of a single phase PSC compressor. C to R is 1.2 ohms, and C to S is 3.5 ohms. What must the resistance be between S and R if the windings are perfectly healthy?

4.7 ohms

400

What year was the HVAC department added to the company

2003

400

Why specifically does pulling a vacuum remove moisture?

Pulling a vacuum causes the boiling point of water to drop (The boiling point of water at 500 microns is -12 degrees)

400

Roughly, what is the torque specification for a 1/4 inch flared fitting for a universal pressure switch?

10-12 ft-lbs

500

What do CFC, HCFC, HFC, and HFO stand for?

Chlorofluorocarbon(r12), hydrochlorofluorocarbon(r22), hydrofluorocarbon(r410a & r32), and hydrofluoroolefin(r1234yf)

500

What is the DS/BK terminal for on a Honeywell Truzone panel?

This is if the HVAC equipment has a DS, BK, ODD, or DHUM terminal. When 2 or 3 zones are calling for cooling, this terminal will be energized, which will run the blower fan at the normal speed. When only 1 zone is calling for cooling the fan runs at a reduced speed which will require less air to be by-passed.


500

Who is the District Manager, Director of Human Resources,  COO, and CEO?

District manager- Steve Bohlman / HR - Rhonda White / COO - Randy Johnson / CEO - Jimmy Hiller

500

According to the fieldpiece manual, how should a triple evacuation be performed?

Purge with nitrogen(to pre-dry the system). Evacuate down to 2000 microns. purge with nitrogen. evacuate down to 1000 microns. purge with nitrogen. evacuate down to below 500 microns. 

500

What specific system is this?

Model # GSXC18036

G- Goodman / S- split system outdoor unit / 

X- Air conditioner / C- Two stage /

18- 18 SEER / 036 - 3 Ton 