This component will lower the pressure and temperature in the refrigerant cycle
Metering device
This component is responsible for converting alternating current to direct current.
An inverter
What is our core value?
CARE
What is considered a deep vacuum?
Below 500 microns
Who invented modern day air conditioning?
Willis Carrier
115-120 degrees
This tool is used to measure air velocity
Anemometer
What would be the cost for an HHC membership for a customer with five systems?
50 dollars a month
Why are decay tests important?
To ensure that no moisture or leaks are present in the system
What does a hydronic system circulate?
Water
Why do gauges show PSIG instead of PSI?
PSIG stands for pounds per square inch gauge. Refrigerant gauges don't account for atmospheric pressure (14.7 psi)
When a system is not coming on, this component is the thing we check
The thermostat
What is this month's HVAC promotions for HHC customers?
25% off on repairs and up to $1500 off replacements
What level of microns is atmospheric pressure at sea level?
14,700 microns
What does the term "one ton of refrigeration" come from?
The amount of heat required to melt on ton (2,000 pounds) of ice over a 24-hour period
What will cause a high delta t?
Evaporator malfunction or low air flow
You measure the resistance of a single phase PSC compressor. C to R is 1.2 ohms, and C to S is 3.5 ohms. What must the resistance be between S and R if the windings are perfectly healthy?
4.7 ohms
What year was the HVAC department added to the company
2003
Why specifically does pulling a vacuum remove moisture?
Pulling a vacuum causes the boiling point of water to drop (The boiling point of water at 500 microns is -12 degrees)
Roughly, what is the torque specification for a 1/4 inch flared fitting for a universal pressure switch?
10-12 ft-lbs
What do CFC, HCFC, HFC, and HFO stand for?
Chlorofluorocarbon(r12), hydrochlorofluorocarbon(r22), hydrofluorocarbon(r410a & r32), and hydrofluoroolefin(r1234yf)
What is the DS/BK terminal for on a Honeywell Truzone panel?
This is if the HVAC equipment has a DS, BK, ODD, or DHUM terminal. When 2 or 3 zones are calling for cooling, this terminal will be energized, which will run the blower fan at the normal speed. When only 1 zone is calling for cooling the fan runs at a reduced speed which will require less air to be by-passed.
Who is the District Manager, Director of Human Resources, COO, and CEO?
District manager- Steve Bohlman / HR - Rhonda White / COO - Randy Johnson / CEO - Jimmy Hiller
According to the fieldpiece manual, how should a triple evacuation be performed?
Purge with nitrogen(to pre-dry the system). Evacuate down to 2000 microns. purge with nitrogen. evacuate down to 1000 microns. purge with nitrogen. evacuate down to below 500 microns.
What specific system is this?
Model # GSXC18036
G- Goodman / S- split system outdoor unit /
X- Air conditioner / C- Two stage /
18- 18 SEER / 036 - 3 Ton