Opposites attract 
Things that spin 
Eat my shorts
Snap Crackle Pop
Who Knows
Not Motors
What's my name
100

this type of magnet is produced by the flow of electric current

Electromagnet

100

a turning or twisting force that causes an object to move

Torque

100

 a device with a fusible link that melts and opens when an overcurrent exists

Fuse

100

A(n)   ?   condition causes the current to rise hundreds of times higher than normal at a very fast rate.

Short Circuit

100

Motors are found in the code book in article?

430

100

Sprinkler head locations can be found on this print.

RCP

100

What is the abbreviation for the power rating of a motor on the nameplate?

HP

200

current in a conductor creates a what around the conductor

Magnetic field

200

the rotating moving part of an alternator or generator or motor consisting of a core and windings

Rotor

200

a set of fuses or circuit breakers added to provide overcurrent protection of a switch circuit is called

Overcurrent protection device / OCPD

200

A __?____  is an unintentional connection between an ungrounded conductor and any grounded raceway, box, enclosure, or fitting.

Ground Fault

200

Overcurrent Protection is found in the code book in article?

240

200

The maximum amount of #10 AWG THHN wires that can be pulled in a 3/4" EMT is?

10

200

The   ?   rating of a motor is abbreviated Hz.

Frequency

300

an electromagnetic device that converts electrical energy into a linear mechanical force that moves a plunger within a coil

Solenoid

300

this type of motor is an induction motor with the squirrel cage conductor bars replaced with coils of wire and with added slippers brushes and a resistor circuit

wound rotor motor

300

a dual element fuse that can detect and remove a short circuit almost instantly but allows small overloads to exist for a short period of time

Time delay fuse/ TDF

300

A(n)   ?   condition causes the current to rise hundreds of times higher than normal at a very fast rate.

Short Circuit

300

This type of OCPD does not need to be maintained.

Fuses

300

A GFCI receptacle will trip at this current amount.

5ma
300

A motor's nameplate voltage rating is the   ?   voltage that should be connected to the motor for best operating performance.

Optimal

400

 the ability of an inductor (coil) in one circuit to induce a voltage in another circuit or conductor is called what

Mutual Induction

400

This type of motor spins at the same speed as the magnetic field. It can also function as an alternator and is commonly used in electric vehicles.

Synchronous Motor

400

the maximum amount of current that can be safely applied to an ocpd while still maintaining its physical integrity when reacting to fault currents

Interruption rating

400

A(n)   ?   in a motor is caused by a load that exceeds the full-load rating of the motor.

Overload

400

During typical motor operation current will be highest during motor startup. This is called the ___?___ current?

Locked Rotor

400

The grounded conductor is this color.

Grey or White

400

How are motors designed to operate for unlimited periods marked on the nameplate?

Cont

500

when an AC source voltage rises and the magnetic field expands around conductors an opposing voltage is induced in the circuit

CEMF or counter electromotive force or back emf

500

 this type of motor is an electric motor that uses the principles of mutual induction to develop current and torque in the rotor

Induction motor

500

 this type of circuit breaker has a delay in time between the fault and when the CB operates. However, the larger the overload or fault, the faster the device operates.

Inverse-time circuit breaker/ ITCB

500

Which type of overload occurs when a motor draws much more current than its full-load current during startup?

Temporary Overload

500

The number of electrical degrees in one rotor revolution depends on the number of      ?     in the motor.

Poles

500

An extension ladder should be set up away from the wall at this ratio.

4:1

500

The actual voltage applied to a motor should be within plus or minus   ?   of the motor's nameplate rated voltage.

10%

M