Compliance, Safety
Compliance, Safety
EKG acquisition
EKG acquisition
100

HIPAA states that patient's EHRs must be protected this way.

What is password protected

100

This is what you use to measure blood pressure

What is a sphygmomanometer

100

This blood vessels is where deoxygenated blood enters the right atrium from

What is the superior/inferior vena cava

100

This is what you do to read a rhythm strip when a patient is extremely tachycardic

What is increase the speed of the machine

200

This is the measure of the force blood pumped against the artery walls

What is blood pressure
200

This is the term that describes a heart rate below 60 beats per minute

What is bradycardia

200

Blood flows from the heart to the lungs from this blood vessel

What is Pulmonary arteries

200

This is the standard speed of an EKG machine

What is 25 mm/sec

300

This is what you violate when you release information without permission

What is patient confidentiality

300

This is a contraindication for a patient to undergo a stress test

What is a patient with congestive heart failure or a patient with an active myocardial infarction

300

These arteries supply blood to the heart muscle

What is coronary arteries

300

This is the control on the EKG machine that increases or decreases the voltage on the EKG tracing

What is the Gain

400

What is the best strategy to protect patient information in regards to physical charts

What is the use of numbers to identify patients instead of names

400

This is how you prepare a patient with a hairy chest for an EKG

What is the use of clippers to remove the hair

400

This forms Einthoven's triangle

What is the Bipolar leads

400

This is how many leads make up the standard or bipolar leads

What is 3

500

This is what you need to get from the patient before performing a stress test

What is a signed consent form

500

This is the purpose of HIPAA

What is patient confidentiality with the increase of storing and handling of patient information

500

This is where you will find the sinoatrial node

What is the right atrium

500

This is what you would expect to see on a 12-lead EKG on a multi-channel machine

What is that each lead would appear differently

600

This is the type of consent when the patient follows you into the exam room, undresses, and lies on the exam table

What is Implied consent

600

This is the appropriate baseline EKG when preparing older patients for a stress test

What is a 12-lead EKG

600
This recorder requires the use of longer lasting silver electrodes

What is a serial EKG recorder

600

This is where you would place the V4 electrode

What is 4th intercostal space midclavicular

700

This type of PPE is needed for airborne precautions

HEPA respirator

700

This is the best place to stand when placing leads V2-V6

What is the patient's left side at the head of the bed

800

This PPE should be used for a patient with droplet precautions

Goggles and simple mask

800

This is what you do if your patient comes c/o chest pain for their stress test 

What is contact the provider

900

This person is responsible for cleaning the EKG machine

The EKG tech

900

This is what you should encourage your patient to reach during their stress test

What is their maximum heart rate

1000

This is the questioning technique that uses open-ended questions

What is skilled interviewing technique

1000

This is an adverse reaction during a stress test

What is dizziness
M