What is the only type of safety helmet to be used on Turner Construction projects?
ANSI Type II (or EN12492) with four-point integrated chin strap
What must be completed prior to any surface penetration activities?
Ground Penetrating Radar (GPR)/Utility Locator
Who is the Florida Senior Business Unit Environmental, Health & Safety Director?
Timothy M. Dare, CSP, SMP, CSMP
At what working height does Turner mandate 100% fall protection
6 feet and withing 15 feet of an unprotected edge or opening
At a minimum, what types of ladders required on Turner project sites?
Type I (300lb) fiberglass podium ladders with podium gates

At a minimum, what type of hand protection must our subcontractors use?
Cut-Level 4 gloves
Per Turner policy, at what minimum depth does an excavation require protection (sloping, trench box, etc.) and proper access?
4 feet
When is hurricane season?
June 1st - November 30th
What is the minimum strength required for a fall protection anchorage point?
Must be capable of supporting at least 5,000 lbs per employee. 
When are guardrails required to be installed on mobile scaffolds?
4 feet
What additional PPE is required when working around studs and pull boxes, tight confines such as between wall studs or above ceiling, and all demo activities?
Cut resistant sleeves
Perimeters of all excavations, regardless of depth, should be protected with what?
Safety fence or guardrails
What is the only soil type in Florida?
Type C
What is Turner's enforcement stance on fall protection violations?
Zero Tolerance![]()
When are outriggers required to be installed on mobile scaffolds?
≥ 58” (Larger outriggers required once scaffold is over 2 frames high)
Which piece of PPE is required when chipping, grinding, drilling overhead, or using powder-actuated tools?
Safety glasses and face shield

At a minimum, how far must spoil piles be stored from the leading edge of an excavation?
2 feet
In Florida's high-heat conditions, what is the primary responsibility of subcontractors regarding worker protection?
Provide shade and cooling measures
What must be used to define the boundaries of a Controlled Access Zone (CAZ)?
"Hard" barriers (guardrails, pennant line flagging, rope, plastic chain, etc.) and associated signage. Caution or Danger tape alone is insufficient!

What is Turner's preferred method for our tradepartners accessing work at height?
Mobile Elevated Work Platforms (MEWP)
How often are employers required to conduct medical fit testing of their employees that utilize respirators?
At least annually (every 1 months)
Who must conduct daily inspections of excavations, adjacent areas, and protective systems before work begins and as needed?
The Competent Person
A "competent person" is a designated individual capable of identifying existing and predictable hazards, with authorized power to take prompt corrective measures to eliminate them.
From what entities are the majority of Turner Self-Perform Operations (SPO) laborers hired from?
Third party staffing agencies

At a minimum, how far back must warning lines be placed from a leading edge?
15 feet
What is required when working above 4' on a ladder?
Fall protection or podium ladder gate