The minimum depth below grade for footings in NC unless frost protection is provided.

 

What is 12 inches? (R403.1.4)

100

The bracing method that uses 1×4 let-in braces at 45°.

What is Method LIB (Let-In Brace)? (R602.10.4)

100

The climate zone for the majority of North Carolina under the 2018 code.

What is Climate Zone 4 (except mountain counties)? (Figure R301.2(4))

100

The minimum diameter of a building drain.

What is 3 inches? (P3005.4.1)

100

The minimum number of 20-amp small-appliance branch circuits required in a kitchen.

What is Two 

200

The two types of concrete allowed for footings without engineering.

What are plain and reinforced? (R402.2)

200

he minimum length of a braced wall panel using Method CS-WSP.

What is 48 inches? (Table R602.10.4)

200

The maximum U-factor for wood-frame walls in Climate Zone 4.

What is 0.082? (Table N1102.1.2)

200

32 inches for 1 inch or smaller 

What is the maximum horizontal support required for PEX piping (cross Linked polyethylene) 

200

the maximum spacing for receptacles in a habitable room along a wall 

what is 12 feet 

300

The NC amendment that requires termite protection for all wood framing within this distance of grade.

What is 18 inches? (R317.1 NC amendment)

300

The NC amendment requiring braced wall lines to be spaced no more than this distance in Seismic Design Category D₂.

What is 25 feet? (R602.10.1.1 NC amendment)

300

 Climate zone for Brunswick County 

What is 3 with an asterisk 

300

The minimum size of a water-service pipe from the street to a single-family dwelling.  

 What is ¾ inch? (P2903.7)

300

This is required on all new services at residential dwellings whether it a changeout, New, substantially improved.  If practical 

What Is a main emergency disconnect ?

400

he maximum allowable soil bearing pressure presumed without a geotechnical report.

What is 1,500 psf? (Table R401.4.1)

400

The bracing method that requires hold-down straps rated for at least 2,000 lb.

What is Method PFH (Portal Frame with Hold-downs)? (R602.10.4.1)

400

The minimum R value for Wood Framed Wall in Brunswick County 

What is R15

400

This pan shall not be less than 1.5 inches deep and sufficient shape and size to receive dripping

What is a Hot Water Heater pan. 

400

Garage Outlets are required to be this 

What is GFCI protected. 

500

The minimum thickness of a monolithic slab-on-grade with turned-down footing in NC.

What is 3½ inches for the slab and 12 inches for the footing? (Figure R403.1(1) & NC amendment R403.1)

500

The total percentage of braced wall panels required on a wall line in Wind Exposure B with 8-ft wall height and no interior gypsum.

What is 16%? (Table R602.10.3(1) – interpolate for 8 ft)

500

 The minimum and maximum design criteria used for heating and cooling loads 

What is 72 degrees for heating max, and a minimum of 75 for cooling?

500

Purple is used as a pipe color when in a residential dwelling 

what is reclaimed rainwater or gray water? 

500

this cable cannot be installed stapled on edge, or unstrapped 8 inches from a single gang box 

What is NMC, non metallic Cable?