Trade terms
Loss of trap seal
Drainage fittings
Sewer systems
DWV potluck
100

The part of the drainage system that extends from the end of the building drain and conveys its discharge to a public sewer,

What is Building sewer

100

This type of trap loss occurs when the house or the figured is not used for a long period of time.

What is evaporation

100

Fittings installed in the drainage sections of the DWV system to remove waste from a building.

What are drainage fittings.

100

This drain carries waste to the portion of the pipe outside that ultimately carries the waste to the city sewer.

What is the building drain

100

The extension of the soil or waste stack above the highest horizontal drain connected to the stack.

what is the stack vent

200

This wastewater comprises 50 to 80 percent of residential wastewater.

What is Greywater

200

This trap seal lose was very common with S traps. This is also something you may do to the jobsite truck's gas tank to remove gas from this truck and put it into yours.

What is siphonage

200

Openings in ell or tee fittings at right angles to the line of the run, used to connect smaller lines to the main line.

What are side inlets.

200

You need one of these access fittings every 100' when running the building sewer

What is a cleanout .

200

The vertical vent pipe installed primarily for the purpose of providing circulation of air to and from any part of the drainage system

what is the vent stack

300

This style trap is found in older homes, now Illegal for new work.

What is a S trap

300

This trap loss occurs here in FL during hurricanes and large afternoon thunderstorms. This happens from large amounts of air entering the DWV system causing the water in the trap to move up and down. This is also something your bedroom floor fan may do when it moves back and forth.

What is Oscillation

300

These fittings are installed in the DWV system so you can check to make sure you have no leaks before the system is put in use.

What are test tees

300

This sewer system is on a private residence. It does not connect to the city main.

What is a septic tank.

300

These sanitary drainage fittings are made with a this design to allow for the smooth flow of material in the system.

what is sweeping design

400

When referred to in DWV and especially sewer systems, the slope of a run of pipe is also considered this. This is also used to judge who you did on a test.

What is grade

400

This " action" happens when something is caught in between the waste line and the trap. such as a string.

What is Capillary action.

400

Drainage fittings that join branches to the main run of pipe at an angle and are shaped like a letter in the alphabet.

What are sanitary wyes

400

This system carries waste from the connection from the house to the municipal treatment plant.

What is a sewer main

400

When installing a DWV system where you will be receiving waste such as fats, oils and grease, you must install this device to prevent the hazards from entering the sewer system

What is an interceptor

500

This term is commonly used in place of speed for describing the motion of fluids in pipes.

What is Velocity

500
This trap seal loss occurs when a combination of speed and mass occurs in the building drain causing water to get sucked out of the trap.

What is momentum

500

When referred to in DWV systems, the pipe end or the male portion of a fitting that inserts into the hub of a downstream fitting.

What are spigots

500

Manholes must be located at this length interval.

What is 400 ft

500

Not only do traps keep sewer gases out of the building, they also prevent this from occurring. 

so you wont get sick!

what are diseases