Residential Wiring (A)
Residential Wiring (B)
2023 NEC (A)
2023 NEC (B)
STE
100

This piping system shall NOT be used as a grounding electrode 

What is metal underground gas pipe 

100

Name a location within a residential dwelling that would require GFCI protection 

What is garage (Answers will vary) 

100

The screw shell of a luminaire or lampholder shall be connected to the _____ conductor 

What is grounded/neutral 

100

Grounded conductors _____ and larger can be identified by distinctive white or gray markings at their terminations 

What is #4AWG   200.6(B)4 

100

The current of two resistors placed in series would be ____

What is equal/same 

200

Which portion of a dwelling is NOT counted when calculating the general lighting and receptacle load 

What is garage (Answers may vary) 

200

The general lighting load demand factor for the first 3,000VA is _______

What is 100%

200

Overcurrent devices shall be installed so the center of the handle in the highest position is not more than ____ above the working platform

What is 6' 7"     240.24(A) 

200

Type AC cable shall be secured within ____ inches of outlet box, cabinet, conduit body or fitting 

What is 12" 

200

A sine wave with an RMS voltage of 120 volts would have a peak value of _____ volts 

What is 170

300

When cables routed through bored holes in joist, rafters or wood members do NOT maintain the minimum 1 1/4" distance from the edge of the wood, a _____ shall be installed to protect the cable. 

What is nail plate 

300

_____ provides protection for personal and trips when their a current imbalance of 4-6ma between the neutral and hot in the load 

What is GFCI 

300

When calculations in article 220 result in a fraction of an ampere less than ____, such fractions can be dropped 

What is .5     220.5(B)

300

The minimum size overhead service conductor permitted is _____ AWG copper or _____ AWG aluminum 

What is 8 and 6 230.23(B)

300

DAILY DOUBLE!! 

The power company supplies _____ power 

(Hint: Beer Glass) 

What is apparent power 

400

Within a panelboard, the overcurrent protection device is connected to the _______ circuit conductor 

What is ungrounded (Hot, black, red) 

400

Often this is used as a grounding electrode in a residential wiring system 

What is ground rod, uffer, H20 pipe 

400

Conductor adjustment factors shall NOT apply to conductors in raceways having a length not exceeding ____ inches

What is 24". Nipple 310.15(C)(1)(b)

400

Rigid metal conduit that is directly buried in a trench below 2" thick concrete shall have at least ____ inches of cover 

What is 6 inches T300.5(A) 

400

The unit of measure for inductors is _____

What is Henrys 

500

The dwelling lighting load demand factor used for 3001-120,000 VA 

What is 35% 

500

The NEC permits an additional demand factor of _____% for the neutral conductor for household electric ranges and dryers 

What is 70

500

Expansion fittings for PVC conduit SHALL be installed when thermal expansion and contraction is expected to be ____ or greater 

What is 1/4"  352.44(A) 

500

Where a feeder supplies a continuous load or combo of continuous and non-continuous loads, the feeder conductor shall have an ampacity not less than the non-continuous load plus_____ % of the continuous load

What is 125% 

500

Magnetic lines of force are called _____

What is flux 

M
e
n
u