AC Components
Maintenance
Troubleshooting

Random
Thermostat
100

This component moves air through the home’s ductwork.

What is the blower motor?

100

Homeowners should regularly replace or clean this item to help airflow

What is the filter

100

A dirty filter can cause what to happen to the indoor evaporator coil

Ice Up / Freeze Over

100

The air-conditioner needs this in order to make cold air and cool the home?

what is refrigerant

100

This device controls the home’s heating and cooling settings

what is the thermostat

200

This outdoor component releases heat from the refrigerant.

What is the condenser coil/unit

200

Maintenance technicians use a hose & water to clean this unit

What are condenser coils/unit

200

A plugged evaporator coil drain line will cause what to happen?

Water will leak outside of the furnace 
200

The air filter goes on which side of the system, the return or supply side?

what is the return

200

A dead version of this small power source can stop some thermostats from working

What is batteries

300

This component helps start and run the compressor and fan motors.

What is the capacitor

300

This is connected to the indoor evaporator coil, technicians will make sure this is clean/clear to prevent condensation water from leaking

What is the condensate drain line

300

If a client calls in and says their AC system is iced up...

What is the first steps they should take before we can send out a technician?

Install a new filter, turn the AC off at thermostat, and turn on the fan until the system thaws out...

Technicians cannot perform any diagnosis until the system has thawed

300

This component is on the outdoor unit and it removes heat from the refrigerant

what is the condenser fan motor / outdoor fan motor

300

What are the 2 settings for the fan at the thermostat?

Auto & On

400

This indoor coil absorbs heat from inside the home.

What is the evaporator coil?

400

This reading is taken with a thermometer, and it is the  difference between return air temp & supply air temp

Temperature Split / Delta T

400

If a client says the indoor unit/furnace is running, they feel only warm air from the vents, but the outdoor unit is not operating...what is most likely the issue?

Bad/Failed dual run capacitor in the condenser unit

400

Clients should not set the thermostat below what temperature to prevent damaging the compressor and icing up the AC system?

what is 68 degrees

400

If the fan is set to “On” at the thermostat, the indoor fan/blower motor will do what?

Run continuously

500

This component pumps refrigerant through the air conditioning system

What is the compressor

500

Technicians hook up their gauges on the outdoor condenser unit to check these readings?

Operating Pressures or Refrigerant Charge/Levels

500

If a client complains the thermostat is set for cooling, the indoor, and outdoor units are running, but they feel only warm air from the vents, and the thermostat will not reach the set temperature....What is most likely the issue?

Low Refrigerant

500

What are 3 pieces of equipment that could be considered an air-conditioner?

Split system AC, Heat Pump, Mini-Split

500

This thermostat setting allows the fan to run only during heating and cooling cycles

What is Auto