Refrigeration Cycle
Safety and PPE
Troubleshooting
Components and Tools
Ammonia Awareness
100

This component absorbs heat from the refrigerated space

What is an evaporator 

100

This piece of equipment protects your eyes from ammonia exposure.

What are safety goggles

100

A high head pressure reading may indicate this condenser issue

What is a dirty or blocked condenser 

100

This tool is used to monitor system pressure 

What is a pressure gauge

100

The chemical formula for ammonia is this 

What is NH3

200

This device compresses refrigerant vapor, raising its pressure and temperature

What is a compressor

200

This must always be worn when handling refrigerants or chemicals 

What are gloves

200

: If the evaporator is covered in ice, this component may be malfunctioning.

What is the defrost cycle 

200

This device electrically energizes to control refrigerant flow

What is a solenoid valve 

200

Ammonia is classified as this type of gas by the DOT

What is non-flammable 

300

This component rejects heat to the outside

What is a condenser 

300

This device is used to detect the presence of ammonia in the air

What is an ammonia detector 

300

This device will shut down the engine room in the event of an emergency 

What is the Emergency Stop Switch (e-stop) 

300

This tool is used to check for leaks in an ammonia refrigeration system

What is a sulfur stick (or PH paper) 

300

The IDLH (immediately Dangerous To Life and Health) concentration for ammonia is this many PPM

What is 300 PPM

400

This device meters refrigerant into the evaporator and causes a pressure drop

What is an expansion device

400

This is the first thing you should do if you smell ammonia in the plant 

What is evacuate the area (or leave the area and move upwind)

400

High counts on this equipment would indicate flood back in a recirculator 

What is a transfer vessel 

400

This component stores refrigerant just before the expansion valve 

What is a receiver (or High Pressure Receiver HPR)

400

Contact with liquid ammonia can cause this type of injury 

What is frostbite (or chemical burns)

500

These four main components make up the basic refrigeration cycle

What is an evaporator, compressor, condenser and expansion device

500

This is the recommended minimum time to flush eyes with water after an ammonia exposure 

What is 15 minutes 

500

High oil cooling temperatures on screw compressors could be caused by low refrigerant in this vessel 

What is a thermosyphon 

500

This component rejects heat where it can do no harm 

What is a condenser

500

This is the first step in First Aid if ammonia is inhaled

What is move the person to fresh air