Handheld
Perimeter
Regulation
Science
Pine Trivia
100

This Aeroqual Product boasts Wi-Fi Connectivity, Long Battery Life, and an Integrated Laser Optical Particle Counter.

What is Aeroqual Ranger PMX?

100

This Aeroqual Product (Dilution Calibrator) gives the user the ability to easily calibrate their own equipment.

What is AirCal 1000?

100

This Comprehensive Federal Law regulates air emissions from stationary and mobile sources.

What is the Clean Air Act of 1970?

100

My formula is CH20

What is Formaldehyde?

100

Pine's second office

What is Pine Atlanta?

200

This Aeroqual Sensor Head provides multiple particulate fractions simultaneously at 1, 2.5, 4, and 10 micron intervals.

What is PMX?

200

This Perimeter Air Monitor can hold 3 Gas Modules and 1 Dust Module

What is AQS1?

200

This 'City of Angels' regulation is titled "____ - Control of Particulate Emissions from Soils with Toxic Air Contaminants".

Key requirements:

•Continuous PM10 monitoring during earth moving activities of impacted soil.

•PM10 contribution must not exceed 25 µg/m³ over 120-minute rolling average.

•Monitoring equipment must be EPA or Rule 1466 approved

•Wind speed and direction must be monitored


What is Rule 1466?

200

Technology that provides VOC baseline stability and lower detection limits than typical PIDs

What is Automatic Baseline Correction (ABC)?

200
He was Pine's first delivery driver

Who Roger Pinheiro?

300

The Aeroqual Ranger logging interval

What is 60 seconds?

300

This Gas Module speciates and measures four gasses simultaneously.

What is BTEX?

300

This "Technical Guidance for Site Investigation and Remediation" was issued on May 3rd, 2010.

Key Requirements:

•Real-time monitoring of particulates and VOCs

•PM10 and VOC contribution must not exceed 150 µg/m³ and 5 ppm over 15 minutes, respectively.

•Specifies minimum performance standards for monitoring equipment.

What is "DER-10"?

300

A unit of length equal to one millionth of a meter.

What is Micron?

300

This Pine employee opened a Pine office which set the standard for all future Pine offices.  It included an accent wall to include the Pine Logo, Slat Board to showcase available consumables, and hosted Pine's first Open House.  

Who is Ted Wittemann?

400

Able to store 8188 records and monitor 14 different gases and PM via interchangeable sensor heads.

What is the Aeroqual S500?

400

This Near Reference Perimeter Air Monitor does not contain a Power Delivery Interface Board.

What is AQM65?

400

Starting in 2024, this is required to monitor and control off-site excursion of dust, vapor, and odors from remediation sites in and around New Jersey.

What is Perimeter Air Monitoring Plan (PAMP)?

400

I use a krypton filled UV lamp. I ionize gas molecules and generate a current that’s proportional to the concentration.

What is a photo ionization detector?

400

This Pine Customer relied on Pine to provide air monitoring training to their employees as it was a requirement to working on the site's of their largest customers.  Who was Pine's customer and who was "their" customer? 

Who are Arcadis and Chevron? 

500

This Aeroqual Service keeps your Sensor Heads Calibrated without any down time.  

What is HotSwap?

500

All Aeroqual Perimeter Air Monitoring Units have this, which states that they do not allow any excess ingress of dust or water jets from any direction.

What is IP 65?

500

The Canadian Air Quality Health Index (AQHI) is measured using the three-hour average concentrations of these three parameters.

O3, NO2, and PM2.5

500
Detecting Gases is my job, my components consist of Membranes, a Reference Electrode, a Working Electrode, Platinum Wire, Counter Electrode, and Acid Electrolyte, and Pins.  

What is Electrochemical Gas Sensors (GSE)?

500

This manufacturer is dedicated to supporting and helping Pine win more perimeter air monitoring projects.  

Who is Aeroqual? 