HEALTH
HEARING CONSERVATION
RESPIRABLE DUST
SPCC AND PROX
TRANSPORTATION AND COMMUNICATION
100

NAME 3 TYPES OF SPILLS THAT MUST BE REPORTED

NON-HAZARDOUS CHEMICALS, GASOLINE, DIESEL, LUBRICANTS THAT EXCEED 5 GALLONS

SPILLS THAT ENTER SURFACE WATER SYSTEMS

HAZARDOUS CHEMICALS

100

NAME THE 3 PARTS OF THE EAR

THE OUTER EAR

THE MIDDLE EAR

THE INNER EAR

100

SHORTNESS OF BREATH, WEAKNESS AND SEVERE COUGH ARE SIGNS OF WHICH 2 IRREVERSIBLE LUNG CONDITIONS

PNEUMOCONIOSIS AND SILICOSIS

100

NAME 6 SPILL MANAGEMENT PRACTICES

AVOID SPILLS

GOOD HOUSEKEEPING

PREVENTATIVE MAINTENANCE

SPILL PREVENTION AND RESOPNSE PROCEDURES

WASTE MANAGEMENT

INSPECTIONS

100

WHAT IS THE FOOTAGE REQUIREMENT FOR TRACKING MINERS UNDERGROUND

 200 FEET SPECIFIED AREAS

2000 FEET PRIMARY AND SECONDARY ESCAPEWAYS

4000 FEET BELTLINES

200

NAME THE 14 INJURY TYPES

SM,SS,SL,SA,CBY,CW,CO,CB,CI,FS,FB,E,FBE,O

200

WHAT IS A DECIBEL

MEASURE OF SOUND PRESSURE

200

NAME 4 CONTROLS TO LIMIT DUST EXPOSURE

WATER, VENTILATION, DUST COLLECTION, AND PPE

200
EXPLAIN THE 3 WARNING SYSTEM ZONES FOR THE PROX DETECTION

OUTSIDE AWARENESS ZONE-GREEN LIGHT ON PROX + EQUIPMENT-NORMAL OPERATION

WARNING ZONE-YELLOW LIGHT AND BEEPING TONE ON PROX + FLASHING YELLOW ON EQUIPMENT-AUTOMATICALLY SLOWS

SHUTDOWN ZONE-CONTSTANT RED LIGHT AND CONSTANT ALARM ON PROX + CONSTANT RED LIGHT ON EQUIPMENT-MACHINE TRAM AND CONVEYOR SWING SHUTS DOWN

200

NAME 5 LOCATIONS THE TRACKING SYSTEM MUST COMMUNICATE UNINTERRUPTED 

PRIMARY AND SECONDARY ESCAPEWAYS, SCSR CACHES, POWER CENTERS, WORKING SECTIONS, REFUGE ALTERNATIVES

300

WHAT IS THE PURPOSE OF A CPDM UNIT

PROVIDE A CONTINUOUS READOUT OF RESPIRABLE COAL MINE DUST CONCENTRATIONS DURING THE WORK SHIFT

PROVIDES LAST 15-MINUTE AVERAGE FOR SHORT TERM SAMPLES

PROVIDES LAST 30-MINUTE AVERAGE FOR FULL SHIFT SAMPLES

STORES SAMPLE DATA FOR FUTURE DOWNLOAD AND ANALYSIS


300

NAME THE 2 TYPES OF HEARING LOSS

TEMPORARY AND PERMANENT

300
WHAT IS THE RESPIRABLE DUST STANDARD

1.5MG/CUBIC METER IN ACTIVE WORKINGS

0.5MG/CUBIC METER WITHIN 200 FEET OUTBY THE WORKING FACES

0.1MG/CUBIC METER OF RESPIRABLE QUARTZ IN ACTIVE WORKINGS

300

NAME THE 6 STEPS OF THE SPILL RESPONSE PLAN

KNOW THE HAZARD AND SAFE HANDLING REQUIREMENTS

STOP THE LEAK

CONTAIN THE SPILL

COLLECT MATERIAL INTO DISPOSAL CONTAINERS

LABEL CONTAINERS PROPERLY

DISPOSE OF PROPERLY

300

NAME 6 OF THE COMMUNICATION AND TRACKING COMPONENTS IN SERVICE UNDERGROUND

IWT RADIO, IWT PERSONAL TAG(TRACKER), ANTENNAS, BEACON, FIXED MESH NODE, BATTERY MESH NODE, PAGER PHONE, LAND LINE PHONE, 

400

NAME ALL 5 CATEGORIES OF THE GCC EYE PROTECTION PROGRAM

SAFETY GLASSES ANSI APPROVED WITH SIDE SHIELDS WORN AT ALL TIMES EXCEPT WHEN IN THE OFFICES, BATHHOUSE, AND PARKING AREAS

PERSONS USING CUTTING TORCHES SHALL WEAR GOGGLES OR SHADE 5 SAFETY GLASSES  WITH A FACE SHIELD

COMBINATION OF SAFETY GLASSES AND A FACE SHIELD SHALL BE WORN WHILE OPERATING GRINDER OR WITHIN 5 FEET OF GRINDING OPERATIONS. SAFETY GLASSES SHALL BE WORN BY ANYONE WITHIN 25 FEET.

PERSONS USING ARC WILDERS OR ASSISTING IN WELDING OPERATIONS SHALL WEAR A FULL FACE SHIELD EQUIPPED WITH A SHADE 10 OR DARKER LENS. AN ELECTRONIC LENS THAT DARKENS WHEN AN ARC IS STRUCK IS ACCEPTABLE

SAFETY GLASSES AND FULL FACE SHIELD SHALL BE WORN WHILE USING COMPRESSED AIR OR HIGH-PRESSURE WATER

400

NAME THE 5 STEPS OF THE HEARING CONSERVATION PROGRAM

MONITORING SYSTEM, HEARING PROTECTION, AUDIOMETRIC TESTING, TRAINING, RECORDKEEPING

400

NAME 5 COMPONENTS OF A CPDM PUMP

SAMPLE INLET ASSEMBLY, SAMPLE LINE(TUBE), BLOCK WITH FLOW RESTRICTOR ORIFICE, GRIT POT, BATTERY, FOAM SPACER, DISPLAY, AIR HEATER, PUMP, SAMPLE FILTER, MASS TRANSDUCER

400

NAME 3 PARTS OF THE PROXIMITY DETECTION STANDARD

EACH MINER IN THE WORKING SECTION MUST WEAR A PROX LOCATOR

A DESIGNATED PERSON MUST PERFORM A CHECK ON THE MACHINE MOUNTED COMPONENTS

CHECK FOR PROPER OPERATION OF THE MINER WEARABLE COMPONENT

THESE CHECKS ARE PERFORMED AND DOCUMENTED IN THE DUST PARAMETERS ONSHIFT BEFORE MINING

PROX LOCATORS MUST BE PROPERLY CALIBRATED BEFORE BEING PUT INTO SERVICE UNDERGROUND 

400

WHAT MUST HAPPEN AFTER THE WEEKLY EXAMINATION REQUIREMTENTS FOR THE COMMUNICATION SYSTEMS INFRASTRUCTURE HAS BEEN COMPLETED

RECORD OF OF THE EXAMINATION WILL BE RECORDED AND MAINTAINED FOR 1 YEAR, ANY REPAIRS/MAINTENANCE WERE COMPLETED AND DOCUMENTED, MADE AVAILABLE TO AN AUTHOURIZED REPRESENTATIVE OF THE SECRETARY, AND COUNTERSIGNED 

500

NAME 9 PURPOSES OF THE MSDS

IDENTIFY

PROPERTIES-CHARACTERISTICS SUCH AS VAPOR PRESSURE OR WATER SOLUBILITY

PHYSICAL HAZARDS- FIRE, EXPLOSION, AND REACTIVITY

HEALTH HAZARDS- SIGNS AND SYMPTOMS, MEDICAL CONDITIONS, ROUTE OF ENTRY

EXPOSURE LIMITS- PERMISSIBLE LIMIT AND MANUFACTURER RECOMMENDATIONS

CARCONOGENICITY- CANCER CAUSING

SAFE USE- HYGIENE PRACTICES, CONTAMINATION, SPILL/CLEAN UP PROCEDURES

CONTROL MEASURE- PPE, WORK PRACTICES, ENGINEERING CONTROLS 

EMERGENCY INFO- EMERGENCY, FIRST AID, AND CONTACT PROCEDURES


500

WHAT ARE THE 3 LEVELS OF THE NOISE STANDARD

ACTION LEVEL 85 DB

PERMISSIBLE EXPOSURE LEVEL 90 DB

DUAL PROTECTION LEVEL 105 DB

500

NAME 5 REQUIREMENTS OF CPDM OR CMDPSU SAMPLING 

SAMPLING IS PORTAL TO PORTAL, ENSURE PROPER LOCATION, FLOWRATE, AND OPERATION, ENSURE ENVIRONMENT IS WITHIN THE DUST STANDARD, CPDM CHECKED AT MIDSHIFT OR WHAT IS SPECIFIED IN VENT PLAN, CMDPSU CHECKED THE SECOND HOUR AFTER BEING PUT INTO OPERATION AND THE LAST HOUR, 2.0 LITERS PER MINUTE CMDPSU, 2.2 LITERS PER MINUTE CPDM, CHECKED WITHIN 3 HOURS PRIOR TO SAMPLING SHIFT, WORN WITHIN 36IN OF BREATHING ZONE, RESULTS TRANSMITTED WITHIN 24 HOURS, DUST DATA RESULTS POSTED WITHIN 12 HOURS, MSHA REPORT OF RESULTS POSTED FOR 31 DAYS, RECORDS SAVED FOR 1 YEAR, 15 VALID SAMPLES FOR DO'S AND ODO'S, 1 VALID SAMPLE FOR DWP, 5 VALID DA SAMPLES, 

500

NAME 5 STRUCTURAL MANAGEMENT PRACTICES

SEDIMENT AND EROSION CONTROL

SECONDARY CONTAINMENT

STORMWATER EXPOSURE CONTROL

MANAGEMENT OF RUNOFF

COVERING OF RAW MATERIALS

500

EXPLAIN THE BACK-UP COMMUNICATION PROCEDURE IN THE EVENT OF THE IWT COMMUNICATION SYSTEM FAILURE

NOTIFICATION OF THE AFFECTED AREA VIA BACKUP COMMUNICATION SYSTEM, INCLUDE THE NATURE OF THE FAILURE, THE EXTENT OF THE SYSTEM AFFECTED BY THE FAILURE, THE MANNER IN WHICH THE FAILURE WILL BE CORRECTED. UNTIL SUCH TIME AS THE SYSTEM HAS BEEN RESTORED TO FULLY FUNCTIONAL MANNER AND THE AFFECTED AREA HAS BEEN NOTIFIED.

M
e
n
u