Air frame Fire Detection systems
Power plant Fire Detection systems
Instrument Systems
Six Pack Instrument Systems
Aircraft Electrical Systems
100
What is the thermocouple fire-warning system activated by?

rate of temperature rise

100

What class is a fuel/oil fire?

Class B

100

What do you call the fixed line in the magnetic compass?

Lubber Line

100

List 4 of the 6 instruments in the six pack.

airspeed indicator, attitude indicator, altimeter, turn coordinator, heading indicator, and vertical airspeed indicator

100

what is a cause of generator brush arcing?

Low spring tension

200

What is the color code for fire extinguisher lines?

Brown

200

What effect does water have on a class D fire?

it causes the fire to burn more violently and may even cause it to explode

200

Why is a Magnetic Compass filled with liquid?

To dampen the oscillation of the float

200

List all the instruments only attached to the static port.

altimeter and vertical airspeed indicator

200

the pole pieces or shoes used in a DC generator are a part of what assembly?

Field assembly

300

What typically occurs when a visual smoke detector is activated?

A lamp within the indicator illuminates automatically

300

How are most aircraft turbine engine fire-extinguishing systems activated?

Electrically discharged cartridges

300

What operating mechanism is found in a hydraulic pressure gauge?

Bourdon Tube

300
List both materials used to make the instrument casings.

Iron or Steel

300
What is the maximum amount of time a circuit can be in operation and still be an intermittent duty circuit?

two minutes

400

What is the correct method to detect the thermal discharge of a built-in fire-extinguisher system?

A rupture of the red plastic disc in the thermal discharge line

400

What is the most satisfactory extinguishing agent for an electrical fire?

Carbon Dioxide

400

What type of thermocouple is used to measure the temperature of the turbine engine exhaust gas?

Chromel and Alumel

400

Where can you find the requirements needed to test or inspect instrument static pressure systems?

(____CFR-part____,Appendix___)

14 CFR-Part 43,Appendix E

400

What must be accomplished when installing an anti-collision light?

Install a switch independent of the position light switch

500

List the correct way to maintenance a fire-detection system.

Replace the damaged elements

500
What is the most common type of portable fire extinguishers available on the ramp?

Carbon Dioxide (CO2)

500

Correctly list all 3 indicators controlled by gyroscopes. (no partial credit)

Attitude indicator

Heading indicator

Turn needle of the turn-and-slip indicator

500

List all 4 discrepancies on an instrument that an aviation mechanic can fix.

(No Partial Credit)

Red line missing

Mounting screws loose

Case paint chipped

Leaking at line B nut

500

How can you determine if a transformer winding has some of its turns shorted together?

Transformer gets hot in normal operation