Chapter 24
Chapter 25
Chapter 29
Chapter 30
Random Question
100

True or False - Two elevations may be drawn on the same sheet.

True 

100

The _____ riser height is 7-3/4".

a) minimum 

b) maximum 

c) average 

d) none of these 

Maximum

100

A stove that has a metal-coated ceramic chamber with a honeycomb design is a _____ stove.

a) circulating 

b) radiant 

c) catalytic 

d) pellet

Catalytic 

100

A(n) _____ switch allows a fixture to be turned on and off from two different locations.

a) single-pole 

b) double-pole 

c) dimmer 

d) three-way

Three-way

100

True or False - When drawing an electrical plan using CADD, specific notes should be placed on their own layer.

True 

200

True or False - The prime considerations in stair design should be appearance and location.

False
200

Which of these statements about a single-face fireplace is false?

a) It is the most common type.

b) It is the least difficult type to construct.

c) It usually functions better than other types of fireplaces.

d) It is also known as a projecting corner fireplace.

It is also known as a projecting corner fireplace.

200

Most electrical appliances are rated in what units?

a) Ohms 

b) Volts 

c) Amps 

d) Watts

Watts

200

Where should service entrance equipment be located?

a) Away from the main breaker.

b) As close as possible to the point where the wires attach to the house.

c) Close to the area of lowest electricity usage.

d) None of these 

As close as possible to the point where the wires attach to the house.

200

No Question

300

_____ stairs require a long, open space that is sometimes difficult to accommodate in a floor plan.

a) Straight Run 

b) L 

c) U 

d) Winder

Straight Run 

300

True or False - If a chimney is located along a single slope of a roof, the chance of water problems is minimized.

False 

300

The _____ consists of the overhead service conductors between the last utility pole and the first point of attachment to the house.

a) service head

b) service entrance 

c) service drop 

d) service panel 

Service Drop

300

True or False - Electric meters can be located either inside or outside the house.

True 

300

No Question

400

True or False - The difference between wide and narrow U stairs is the horizontal space between the flights.

True 

400

True or False - The heat recirculation feature in prefabricated metal fireplaces draws air in from the room, heats it, and returns the warm air to the room.

True

400

True or False -  An individual circuit is a type of branch circuit.

True 

400

Which of the following alternatives to traditional lighting contains mercury?

a) Light-emitting diode (LED) lights

b) Electron-stimulated luminescence (ESL) lights

c) Compact fluorescent lightbulbs

d) None of these 

Compact fluorescent lightbulbs

400

No Question

500

_____ stairs are used when there is not enough space for L, double-L, or U stairs.

a) spiral 

b) circular 

c) straight run

d) winder

Winder

500

True or False - Circulating stoves can be placed closer to combustible material than radiant stoves.

True 

500

True or False - All receptacles installed in bathrooms and garages must have GFCI protection.

True 

500

Which of the following is not necessary on an electrical plan?

a) The number of branch circuits required.

b) The type of branch circuits required.

c) Specification of the exact circuit for each outlet.

d) All of these 

Specification of the exact circuit for each outlet.

500

No Question