Pulse Ox Basics
Clinical Implications
Data & Stats
Optical Physics
WTF was That
100

This is being estimated by a pulse oximeter

Blood Oxygen Levels (SpO2)

100

This medical condition occurs when blood oxygen levels are low - often below 92%.

Hypoxemia

100

This type of regression analysis was used to assess slope and intercept differences across trials.

Linear Regression

100

This skin pigment is largely responsible for red-light absorption in the epidermis.

Melanin

100

This metric of 'peakiness' helps assess whether a pulse oximeter signal was 'sharp' or 'flat'

Kurtosis

200

Pulse oximeters typically use these two wavelengths to measure oxygen levels

Red & NIR

200

This phenomenon, where hypoxemia is missed due to overestimated oxygen levels by pulse oximeters, is twice as likely in black patients. 

Occult Hypoxemia

200

This statistical test was used to compare paired results across pigmented and nonpigmented datasets

Paired T-Test

200

This skin pigment is largely responsible for red-light scattering in the epidermis.

Melanosome

200

This plotting library was used for real-time data visualization. It's fast...

Fastplotlib

300
Pulse oximetry calculates blood oxygen levels using this ratio, derived from red and near-infrared light absorbance

Modulation Ratio (R)

300

Pulse oximetry has largely supplanted the use of this gold-standard method for measuring blood oxygen levels.

Arterial Blood Gas Test (ABG)

300

The authors used this spectral domain method to extract frequency-based features of pulse oximeter data

Fourier Transform

300

A variant of this law, used in the study's model, relates absorbance to concentration, path length, wavelength, and depth.

Beer-Lambert's Law

300

Light-Tissue interactions can be divided into transmission, absorption, reflection, and this.

Scattering

400

There are two components extracted when measuring light absorbance: the baseline (DC) component, and this.

pulsatile (AC)

400

According to Medicare, blood oxygen levels below this threshold can qualify a patient for home oxygen. 

88%

400

When comparing the modulation ratio (R) and true oxygen saturation using a linear regression, a reduction in this parameter indicates reduced sensitivity of the pulse oximeter to changes in oxygen levels.

Slope

400

The author's used this animal model, featuring dual-pigmented skin regions, for their experiment.

Hampshire Pig

400

The authors added this coefficient to account for light lost as it travels through tissue.

Attenuation Coefficient

500

The pulsatile (AC) component of absorption is directly affected by this category of blood vessels.

Arteries

500

The study shows that reduced sensitivity of light absorbance for this color accounts for the racial bias in pulse oximetry.

Red

500

The use of this metric allows us to determine how consistently pulse oximeters perform on similar pigmentations.

Inter-Location Regression

500

Melanin has a higher absorbance in this wavelength region, thereby affecting pulse oximeter accuracy.

Red (660 nm)

500

This mathematical operation was used to model how a real-world LED (with spectral spread) interacts with the absorbance spectra of melanin and hemoglobin.

Convolution