EMS Protocol
RIT
Incident Command
Driver/Operator
Hodge Podge
100
current Compression to Ventilation ratio for adult CPR
What is 30:2
100
Location,___________, name, air supply, resources form the LUNAR mayday declaration.
What is Unit
100
This standardized reporting system is utilized nationally to report Fires and incidents managed by a Fire Department.
What is NFIRS
100
smooth bore nozzles on handlines should be operated at this pressure.
What is 50 psi
100
Water, when converted to steam, expands at this ratio
What is 1700:1
200
This drug, and dosage, is the Macomb County EMS protocols "first-line" medication for Adult Asystole.
What is Epinephrine 1:10,000, 1 mg (10 ml) IV/IO, repeat every 3-5 minutes.
200
This position is responsible to secure the Air supply whether it be a regulator swap or a full mask change.
What is Air/Nav
200
This section of the Incident Command system is responsible for directing personnel at the scene of an incident.
What is the Operations section
200
The standard for the Inspection, Maintenance, Testing, and Retirement of In-Service Automotive Fire Apparatus
What is NFPA 1911
200
At this threshold or level, personnel checking Carbon Monoxide leaks must immediately exit the dwelling and don their SCBA before re-entry
What is 30 ppm
300
Acquisition of this , along with the relay of the results to the receiving hospital, improves time to treatment for acute myocardial infarction
What is a 12 lead EKG
300
This position attempts to find a secondary, or immediate, means of egress once the downed firefighter has been located.
What is Search 2
300
This section of the Incident Command system is responsible for communications.
What is the Logistics Section
300
PDP = ?
What is NP + FL + EL + AL
300
This agency recently conducted independent studies of fire spread based on fire ground staffing levels
What is NIST
400
This fluid, amount, and rate is protocol for the treatment of Heat Stroke.
What is NS IV/IO fluid bolus up to 1 liter, wide open.
400
This member is responsible to ensure the crew maintains adequate air supply to allow for their own egress.
Who is the RIT Officer
400
To prevent, prepare for, respond to, and recover from terrorist attacks, major disasters, and other emergencies, the United States Government established this single, comprehensive approach to domestic incident management.
What is NIMS
400
the formula to determine Back pressure on a Fog Nozzle
What is Q/2
400
Nozzles that adjust their GPM based on delivered pressures
What is a Automatic Nozzle
500
This drug, and dosage, is protocol for pregnant seizure patients in which Eclampsia is the cause.
What is Magnesium Sulfate 2 gm over 10 minutes IV/IO until seizure stops.
500
This maneuver is one option utilized as a means to remove a downed firefighter from below grade
What is the Nance Drill
500
Implemented February 28, 2003 this document mandated use of the National Incident Management System.
What is Homeland Security Presidential Directive-5
500
The minimum residual pressure that should be maintained on the LDH intake hose, if possible
What is 20 psi
500
These types of private fire protection valves display the words "Open" or "Shut" as they approach one position or the other.
What is a Post Indicating Valve
M
e
n
u