Air Basics
Airflow
Controls
Electrical
Miscellaneous
100

These characteristics increase as air is compressed

Pressure and Density

100

This valve regulates the amount of air that enters the airend

Inlet Valve

100

Once the cause of the alarm has been corrected, this must occur in order to clear an alarm condition on an Xe controller

Press the reset button (red triangle)

100

This heat protection device acts as mechanical backup and trips at 245°F (118°C)

High Air Temperature Switch (1ATS)

100

This test measures the health of stator winding insulation

Megger Test

200

This environmental factor has the highest impact on CTD

Humidity

200

This valve ensures minimum coolant flow throughout the machine during unloaded operation

Minimum Pressure Check Valve (MPCV)

200

This starter configuration reduces motor inrush current by 2/3

Star/Delta (Wye-Delta)

200

This device is either normally open or normally closed and creates pathways in a star/delta starter system

Auxiliary Contact

200

This is the maximum allowable tolerance when aligning a gearcase to a main drive motor

+/- 0.001"

300

This is the proper range for unloaded sump pressure in an R-Series machine

18-24 psi

300

This model controller can act as a main motor overload protection device, using current transformers (CTs) to directly monitor main motor current

Xe-70m Controller

300

This sensor shuts the compressor down if airend discharge temperature exceeds 228°F (109°C)

Airend Discharge Temperature Thermistor (2ATT)

300

This must not drop below 10% of nominal when starting and 6% of nominal while running

Incoming Voltage

300

This device controls the volume of coolant that flows through the cooler

Thermostatic Control Valve (TCV)

400

The weight of the molecules in a given volume of air

Density

400

This is a normally open valve that helps control sump pressure and requires AC voltage to close

Blowdown Valve (3SV)

400

This sensor monitors inlet filter health on a rotary compressor

Inlet Vacuum Pressure Transducer (1AVPT)

400

The DC logic voltage level applied to the E-stop from an Xe-90 controller

24 Vdc

400

These control radial forces, support the weight of rotors, and prevent rotor movement due to thrust

Bearings

500

Atmospheric air pressure is directly proportional to density and inversely proportional to this

Temperature

500

These indicate the number of ways in a valve diagram

The number of penetrations (connection points) of any single position

500

This sensor has an input voltage of 5Vdc and returns a resistance signal to indicate package discharge air temperature

Package Discharge Temperature Thermistor (4ATT)

500

This type of signal provides a range of continuous, variable values to the controller

Analog signal

500

This reference provides information for conducting and evaluating coolant samples, air coupons, water samples, and SPM data.

Diagnostics Manual