Weigh-Out
Transfers
Read/Posco
Media
Lab Things
100

Finished product Twix, Combos, and M&M's all have one thing in common.

What is they are processed in STR?

100

Fraser Broth refers to the secondary enrichment for which machine method.

What is Listeria Vidas?

100
This statement will appear of the final COA if the client request any changes to testing that stray from the standard SOP.

What is a deviation disclaimer?

100
The boiler produces this necessary component of an complete autoclave run.

What is steam?

100

A specific type of PPE that must be worn whenever handling sample or sample materials including media.

What is a lab coat?

200

This is the amount of time you have between hydrating samples and pipetting them.

What is 15 minutes?

200

This is the name of the maintenance kit that must be preformed on the vidas machines bimonthly to detect abnormalities in the instruments pipette mechanisms and optical systems.

What is QCV?


200

No matter the scenario. This team of knowledgeable Deibel associates have to be contacted before the client in the event of presumptive client results.

Who is the Presumptives team?

200

This part of the lot number aides in the traceability of the media. It would allow an auditor to easily understand which run of the day the lot was.

What is the batch number?

200

This is something that is done at the beginning and end of the day in each area around the lab.

What is temps?

300

Vidas, PCR, and Gene-up. These are all  ----------- test.

What is qualitative .

300

The GENE-UP platform requires this this daily before samples are run.

What is the Self Test?

300

What must be done at the end of each month to prepare cultures for use next month?

What is purity checks?

300

------ must be run weekly in every autoclave including the market forge.

What is spores?

300

This SOP outlines the process of shipping samples, cultures, and equipment including documentation requirements, packing needs, and preferred vendors.

What the 159 or Chain of Custody?

400

You receive a client SARF indicating the sample requires salmonella real time pcr testing. This is a test that you are largely unfamiliar with. Where do you go to find information about processing this sample?

What is the SOP or Sharepoint to look up SOP?

400

This type of method control error on PCR commonly occurs if there are machine problems, missing pellets, or if the machine needs to be cleaned. The graphs usually has no peaks or internal control lines.

What is signal error?

400

This set of plates point to a ________ salmonella presumptive.

XLD: yellow colonies with black centers

HEK: orange/pink colonies with no black centers.

BS: Dull brown or green colonies with no metallic sheen.

Chrome: Blue colonies.

What is atypical salmonella presumptive?

Extra 100 points to whoever can tell if its atypical H2S positive, atypical salmonella, or atypical non-salmonella growth.

400

This salmonella secondary enrichment media is autoclaved at a lower temperature to help preserve the selectivity of the medium while still allowing for the survival of the target organism. What is the media and what is the temperature?

What is RV and 115 degree C?

400

This document holds all information regarding the Deibel life cycle of any supply item that we receive. This includes vendor info, open date, storage area.

What is the 1111-1.

500

Environmental Listeria pcr presumptive with the following reactions:

Typical growth on MOX/OX/ALOA. No halos on ALOA. Isolates taken to Motility and TSB-YE. All isolates were catalase positive and showed tumbling but Umbrellas are still growing and not ready to call.

Give the next step.

What is set up an API?

M