maybe motors
contacts and overloads
definitions
section review
homework questions
100

these loads can be controlled by contactors without overload protection

What are non inductive loads

100

 If a different current range is required for an IEC fixed heater overload relay, this must be replaced.

What is the entire overload relay?

100

This is the repeated opening and closing of the circuit to start and stop a motor

What is jogging

100

And or and not

What are the three basic lpgic functions

100

These relay contacts remain open when the coil is de-energized.
 

What are normally open (NO) contacts?

200

This is the voltage at which a relay's armature overcomes the spring and closes the contacts

What is the pick-up voltage

200

These are the three published ratings for relays and similar devices.

 What are voltage, current, and horsepower (or VA)?

200

These loads can be controlled by contactors without overload protection.

What are noninductive loads?

200

A circuit breaker can be used as a controller for small stationary motors under what horsepower (hp)

What is 1/8th hp

200

The The temperature or pressure difference between the point where a switch activates and the point where it resets

What is Deadband

300

Theas relay contacts remain open when the coil is de-energized

What is normally open

300

This is a contact device that is mechanically connected to a contactor. it can be used to give an electrical signal related to the contactors position

What is a auxillary contact

300

Repeated closing of a circuit to start and start a motor

What is jogging

300

Switch phases 1 & 3

What is how do you reverse a 3 phase motor

300

A switch with contacts that return from the operating position to release the position when the actuating force is removed

What is a momentary contact switch

400

When replacing contactor contacts you must replace these for all poless

What are all moving and stationary contact

400

These are the three relay contact and pole designations.

What are SPST, SPDT, and DPDT?

400

 A relay designated as 3PDT-SB has three normally open and three normally closed contacts.
 What is false?

 What is false?

400

A circuit breaker can be used as a controller for small portable motors under what horsepower (hp)

1/3hp

400

A switch with contacts that remain in the operating position after the actuating force is removed

What is a maintained contact switch

500

These three are the published ratings for relays and similar devices

What are voltage current and horsepower

500

Overload protection for motors is provided by 

 A overload relay

500

This can be classified as an overcurrent that exceeds the normal full load current of a circuit

What is overload

500

This device provides overload protection for motors.
 

What is an overload relay?

500

This is the voltage at which a relay’s armature overcomes the spring and closes the contacts.

What is pickup voltage?

M
e
n
u