Compressor
Evaporator
Condenser
Metering Device
Evacuation/Charging
100
Moves refrigerant through the system, increases pressure and temperature

What is the Compressor

100

is a coil of metal tubing, responsible for absorbing heat from the refrigerant cycle

What is the Evaporator

100

state of the gas when it leaves the condenser

what is high pressure liquid refrigerant

100

opens the needle and seat on a TEV

what is sensing bulb pressure

100

the vapor side of a recovery bottle is determined by 

what is read the valve handle

200

a compressor in which all the components are sealed inside of its casing.

What is Hermetic

200

the type of heat that is absorbed in the evaporator

what is latent heat

200

enters the condenser

what is high pressure vapor refrigerant

200

the purpose of the TEV/ metering device

what is to maintain superheat

200

recommended vacuum amount, ensures there is no moisture left in the system

what is 500 microns

300

primary function is to trip compressor offline when compressor windings overheat.

What is Motor Protection Module?

300

This is used to move air across the evaporator to apply heat load to the refrigerant system

what is the evaporator fan

300

De-superheat, condense , Subcool

what are the three phases of the condenser

300

this has to be overcome by the sensing bulb to open the needle and seat on a txv

what is the spring pressure and equalization pressure

300

a recovery unit that does not use the system to evacuate the refrigerant

what is a stand alone recovery unit

400

this is used to cool the compressor

what is cool compressor suction gas, and refrigerant flow
400

what is the evap "rule of thumb" for superheat

what is the average of 10 degrees, range 5-20 degrees

400

this is done by taking saturated temperature and subtracting it from liquid line temperature

what is subcooling

400

when ___ ___ ___ overcomes the bulb pressure and closes the valve, effectively increasing your superheat

what is increasing spring pressure of the txv

400

should be done before you charge a system with your gauges

what is purge your gauges of air

500

this is used to prevent flooding and slugging starts

what is the crank case heater, and liquid line solenoid

500

a superheat of over 20 degrees is ___ the evaporator

what is starving

500

a system that has a subcool of over 20 degrees in an ambient temperature of 95 degrees, and a superheat of 5 degrees

what is overcharged, and miss adjusted txv

500

__ + __= Diaphragm pressure

what is Spring pressure + evaporator pressure
500

these are the three R's of refrigerant

what is reclaim, recycle , recover

M