General Information
Symbols & Outlets
Branch Circuits
Wiring Methods
Identification & Grounding
100
The equipment that one wears for their own safety
What is PPE
100
Other than a conductor, this carries or controls electrical energy as it's primary function
What is a device
100
The circuit conductors between the final overcurrent device and outlet(s) are called this
What is a branch circuit
100
The maximum current that a conductor can carry, under the conditions of use, without damage to the conductor insulation
What is ampacity
100
The conductor that has white of gray insulation
What is the grounded (neutral) conductor
200
One who has the skills and knowledge to recognize and avoid safety hazards
What is a competent person
200
The amount of free conductor required at a device box
What is 6 inches
200
A load where the maximum load is expected to continue for three or more hours
What is a continuous load
200
The ampacity table
What is Table 310.15(B)(16)
200
This conductor is connected to the narrow slot on a duplex receptacle
What is the ungrounded (hot) conductor
300
The setback ratio for extension ladders
What is 4:1
300
This type of box will accept three devices
What is a three gang box
300
This is the maximum continuous load allowed on a 20 ampere circuit
What is 16 amperes
300
The maximum load on a 20 ampere branch circuit that is NOT a continuous load
What is 20 amperes
300
All residential receptacles are required to incorporate this safety feature
What is tamper resistance
400
This is required by and obtained from the AHJ before beginning most electrical projects
What is a permit
400
The minimum size box without internal clamps (in cubic inches) required for 2-14/2 cables and one device
What is 14 cubic inches
400
Number of receptacles required in a 9' 11" hallway
What is none
400
This type of conductor is no longer allowed to be used for switches and receptacles
What is aluminum
400
All switching must be done in this conductor
What is ungrounded (hot) conductor
500
NFPA 70
What is the National Electrical Code
500
This must be provided in all metal boxes for safety
What is a means of grounding
500
The amperage rating of the circuit for a bathroom is required to be this.
What is 20 amperes
500
Non-metallic sheathed cable is required to be secured within 8 inches of this type of box
What is a non-metallic single-gang nail up box
500
The conductor supplying power to a three-way switch must be connected to this terminal
What is the common terminal
Continue
ESC
Reveal Correct Response
Spacebar
M
e
n
u
Team 1
0
+
-
BCT Residential Wiring
No teams
1 team
2 teams
3 teams
4 teams
5 teams
6 teams
7 teams
8 teams
9 teams
10 teams
Custom
Press
F11
Select menu option
View > Enter Fullscreen
for full-screen mode
Edit
•
Print
•
Download
•
Embed
•
Share
JeopardyLabs